background image

 

4

 

 
 
 
 

The Endorphin 

e

1-

MAG

 resistance system is designed to be accessible, easy-to-use, and allows 

the user to train independently.  Tried, tested, and proven in rehab facilities and homes, the 

Endorphin 

e

1-

MAG

 resistance system delivers excellent upper-extremity muscle conditioning and 

improves cardiovascular capacity.  A bi-directional magnetic resistance flywheel design means 
less noise and a frictionless resistance versus traditional friction belt-type hand cycles.  A multi-
function electronic monitor which reads distance, time, speed, calories, and pulse.  Comfort grip 
handles are provided to allow the user to rotate his arms forward and reverse.  The bi-

directional flywheel on the 

e

1-

MAG

 allows the user to exercise with resistance in both the forward 

and reverse directions.  The adjustable magnetic resistance features 8 workload levels, which 
allows the user to have smaller resistance changes.   
 

INSTRUCTIONS:

 

 

1. Hand 

Grips

: The handgrips are clearly marked at the threaded end of the grip, L for left 

and R for right.  Install the L grip into the hand crank on the left-hand side of the cycle.  
Turn it counter clockwise to tighten.  Install the R grip into the hand crank on the right 
side of the cycle.  Turn it clockwise to tighten.  A small adjustable wrench should be 
used to securely tighten the grips into the hand crank.  The handles should rotate freely 
on the threaded rods.  In the 370 Series platform format the handles may have been 
attached at the factory.

 

 
2.  Electronic Exercise Monitor

: Our flexible power system allows the unit to operate 

using batteries or with a power adaptor provided.  Secure the monitor on the monitor 
bracket and connect the control and sensor cables.

 

Option 1: Install the batteries into the monitor as described in the monitor instructions 
(located in the parts box with the monitor).

 

Option 2: The unit may also be powered with the adaptor provided.  Note: Please 
remove the batteries if installed then plug the adaptor cable into the back of the monitor 
then plug the adaptor in to the wall (120V).  Plug-in the Ear Clip into the front of the 
meter if required.  Ensure that the Ear Clip cable does not get caught in the hand crank 
when it is rotated. 

 

3. Resistance Adjustment

: Please follow the operating instructions provided with the 

electronic monitor (located in the box covering the monitor) 

 

4. Power 

Supply

: The AC adapter 6VDC monitor and servo power supply requires a 120V 

60Hz 25W outlet.  We recommend that you use a surge protector type plug and then 
plug that into the outlet. 

 

5. Exercise

: Adjust the resistance with the adjustment lever and start the electronic meter.  

 

Take hold of the handles and begin to rotate them in a forward or reverse motion.  The 
resistance may feel harder at the start but will become less as the flywheel builds up 
momentum. 

 
 
 
 

Summary of Contents for 370-e1 Series

Page 1: ...or rm m I In ns st tr ru uc ct ti io on n M Ma an nu ua al l Expandable Modular Technology The only exercise equipment line with interchangeable upgradeable resistance systems that safeguard against o...

Page 2: ...semi recumbent seat is orthopedically designed for even weight distribution The seat adjusts front to rear for proper user positioning and rotates 360 degrees to provide easy access The seat assembly...

Page 3: ...is supported and it may not move in either direction when the lever is moved 3 Place hands on the arm crank handles 380 arms only and feet on the foot crank With back supported by the seat adjust the...

Page 4: ...the grips into the hand crank The handles should rotate freely on the threaded rods In the 370 Series platform format the handles may have been attached at the factory 2 Electronic Exercise Monitor O...

Page 5: ...ips are secured in position using a wrench and are not just hand tight 2 Ensure that the rubber handgrip rotates on the threaded shaft If not please return the part to your supplier for a replacement...

Page 6: ...ise to tighten A small adjustable wrench should be used to securely tighten the grips into the hand crank The handles should rotate freely on the threaded rods In the 370 Series platform format the ha...

Page 7: ...osition using a wrench and are not just hand tight 2 Ensure that the rubber handgrip rotates on the threaded shaft If not please return the part to your supplier for a replacement Problem When the han...

Page 8: ...ht hand side of the cycle Rotating the nut away from you to tighten To change the handles simply remove the handle from the crank arm by rotating the nuts towards you and replace with either 22 degree...

Page 9: ...r handgrip rotates on the threaded shaft If not please return the part to your supplier for a replacement Problem When the handles are rotated the chain does not engage the flywheel Answer Check that...

Page 10: ...re operated and controlled independently and give the user flexibility in customizing treatment or a workout The only upper and lower body system with a height adjustable upper resistance module A sem...

Page 11: ...replaced at no cost excepting labor for the remainder of the warranty period thereafter In certain cases to avoid any undue delay Endorphin may at its discretion replace a product with a factory refur...

Page 12: ...12 The Endorphin Corporation Attn Warranty Registration Dept 6901 90th Avenue North Pinellas Park FL 33782 U S A PLACE STAMP HERE...

Reviews: