For your own safety

•  The Akkulift

®

, charging unit and storage battery 

are  of  robust  construction,  but  should  not  be 
 allowed to fall. Should any visible or audible da-
mage be detected, Akkulift

®

 must no longer be 

used.  In  this  case  please  contact  your  dealer. 
We recommend, filling in the dealer contact in-
formation on the last page of this manual.

•  For  further  information,  technical  details  and 

addresses, please read the entire operating in-
structions.

•  In the event of a failure, please read the supple-

ment  to  these  operating  instructions  and  the 
“Troubleshooting” chapter. Make sure to obser-
ve the information and instructions given there. 
For your own safety you should not use Akku-
lift

®

 in the meantime, until the fault has been re-

medied.

 

Important safety regulations

a)  Always sit in the middle of the lift , stretch your 

legs forward slightly and place your free hand 
either on the edge of the bath or on your lap. 
Using  the  other  hand,  regulate  the  Akkulift

®

 

movement up or down.

b)  Whilst raising or lowering Akkulift

®

, do not place 

your hands between the edge of the bathtub 
and Akkulift

®

 or under the seat of the chair, as 

this can cause injuries.

c)  Persons  with  severe  physical  handicaps  or 

mentally  disturbed  persons  should  never  be 
left unattended in the bath.

d)  Before using the bath lift, a test run should be 

carried out (for raising, lowering and stopping, 
and  also  for  checking  the  Emergency-Stop, 
the red button on the hand control).

e)  If  a  malfunction  has  occurred,  please  do  not 

operate Akkulift

®

, but contact your dealer and 

ask him to remedy the problem.

f)  Do not take any objects into the bathtub when 

bathing!

  Note concerning Electromagnetic 

Compatibility (EMC) 

The electrical drives are confirmed to be compliant 
with the protection requirements set forth in The 
Council Directive for the Harmonization of Legal 
Stipulations  of  the  Member  States  concerning 
Electromagnetic Compatibility (86/336/EWG).
However, the occurrence of electrical interference 
cannot be ruled out completely under certain con-
ditions, i.e. in particular, if mobile phones or other 
electrical devices are used. 

In the vicinity of the bath lift, do not operate any 
life-preserving  or  life-supporting  devices  or  any 
devices that may cause health hazards for users 
in the event of malfunctions. Such devices may 
be subject to electrical interference under certain 
conditions,  or  they  may  adversely  affect  the 
 proper functioning of the bath lift.

If you should detect any malfunctions or unusual 
behavior of your bath lift or in the vicinity or during 
the operation of other electrical devices, please 
make  the  bath  lift  inoperative  and  notify  your 
 specialized dealer. 

Summary of Contents for Akkulift

Page 1: ...Operating Instructions Akkulift Bath lift FELIX English...

Page 2: ...tub 14 Maintenance and care 16 Maintenance of the Akkulift 16 Maintenance of covers 16 Assembly of new cushion plugs for cover of Akkulift 16 Maintenance of the charging unit 17 Charging of 12 Volt st...

Page 3: ...ting position Akkulift can also be adjusted to variable positions The drive is housed in a sealed hood the control electronics in the sealed hand control It is there fore also possible to use Akkulift...

Page 4: ...tain the Akkulift in a perfect hygienic con dition Do not use any detergents containing acetic acid for cleaning the Akkulift The charging unit must only be used outside the bathroom in a dry environm...

Page 5: ...should never be left unattended in the bath d Before using the bath lift a test run should be carried out for raising lowering and stopping and also for checking the Emergency Stop the red button on t...

Page 6: ...tructions 7 4 x Suction cup transparent for assembling on the underside of base plate Installation and use If one of these parts should be missing please inform your dealer Unpack the charging unit fi...

Page 7: ...The rear suction cups should be located at the bevelled edge of the bathtub 4 Make sure that the lever for the central suction cup black is in a raised position Now press down the suction lever PRESS...

Page 8: ...l in one hand and pull it away from the lift until the cable is slightly tensioned 7 Take the hand grip with the other hand and fold up the backrest until it reaches the stop position of the base plat...

Page 9: ...risk that the backrest is pushed against it the lift must be installed outside the bathtub and driven to its upper position before it is placed into the bathtub again However it may be possible that t...

Page 10: ...lation and use Attaching removing covers The covers can be attached and removed very easily To fix the cover place it correctly on the backrest plate seat and press the fastening buttons com Backrest...

Page 11: ...obs from the side flaps and seat with two fingers The bath lift can also be used without covers Seat Cover Installation head rest optional Insert the two guide rods of the headrest into the two holes...

Page 12: ...mediately see Charging the Storage Battery The charging status of the storage battery is mo nitored by electronic control elements After one lifting movement the storage battery needs ap prox 30 secon...

Page 13: ...est on the sides of the bathtub 4 If the bathtub is too tall to allow side flaps to lay flat then you can use available height adapters purchase separately to raise your lift to the proper height Heig...

Page 14: ...lap If the lift is to remain inside the bathtub then remove the battery from the battery compartment This will prevent unintended discharging of the storage battery Installation and use Removing the l...

Page 15: ...te The backrest cannot be removed from the frame when it is completely fol ded down to the seat because the backrest is then in a locked position again Lift the backrest to the angle as shown fig and...

Page 16: ...an be machine washed up to 140 F using a non bio washing powder detergent which does not contain any enzymes Please be aware that any oil based pro ducts that you add to your bath water may stain the...

Page 17: ...type 400350 into the outlet The charging process will be started automatically 3 Check if the battery charging indicator is lit up LED lights 4 For the meaning of the LED colors pls see separate instr...

Page 18: ...ing or slipping during transportation 3 If Akkulift was exposed to low temperatures e g storage in a vehicle during the winter allow it to warm up to room temperature before use and recharge it if nec...

Page 19: ...th of base plate approx 21 5 Load max 308 lbs Weight incl storage battery approx 34 8 lbs Weight storage battery approx 2 2 lbs Motor unit without battery approx 15 lbs Seat unit approx 17 6 lbs Durat...

Page 20: ...width of base plate 12 2 height of backrest 22 depth of seat 17 7 sitting height max 16 1 length of base plate 21 5 overall length of seat 22 75 12 40 sitting height min 3 angle of inclination backre...

Page 21: ...ailure Contact your specialist dealer Do not use the device any longer Storage battery failure Insert new storage battery Lift creates loud noise Defective end stop Contact your specialist dealer Do n...

Page 22: ...lify for our warran ty the customer must present an original invoice delivery note or date stamp of the authorised dealer Damage due to natural wear or improper treat ment is not part of our warranty...

Page 23: ...400350 Stopper and washer for cover Classic Comfort 1 piece white 415252 Stopper and washer for cover Classic Comfort 1 piece blue 415312 Suction cup 2 transparent 400855 Suction cup 3 black 400900 S...

Page 24: ...general technical remarks on the product la bel there are two entries which are important for maintenance repair and guarantee claims WW YY Indicates the year and week of production of Akkulift SN In...

Page 25: ...ns 5 Head rest 11 23 Height adapter 13 23 Note concerning Electromagnetic Compatibility EMC 5 Inserting the Akkulift into the bathtub 7 Installation and use 6 LED lamp 17 Lever of suction cup 7 Liftin...

Page 26: ...e Medical Please enter your specialist dealer s address USA Drive Medical Design Manufacturing 99 Seaview Boulevard Port Washington NY 11050 Attn Customer Service Phone 877 224 0946 Fax 516 998 4601 E...

Reviews: