Installation
CNGmass DCI
14
Hauser
Installation in control panel
1.
Prepare the opening in the panel
2.
Slide the housing into the opening in the panel from the front.
3.
Screw the fasteners onto the wall-mount housing.
4.
Screw the threaded rods into the holders and tighten them until the housing is secured on the
panel wall. Afterwards, tighten the locking nuts.
Additional support is not necessary.
A0001131
Fig. 8:
Panel installation (wall-mount housing)
Pipe mounting
The assembly should be performed by following the instructions in
"
Caution!
If a warm pipe is used for installation, ensure that the housing temperature does not exceed the
permitted value of +60 °C (+140 °F).
A0001132
Fig. 9:
Pipe mounting (wall-mount housing)
245 (9.65)
~110 (~4.33)
210 (8.27)
+0.5 (+0.019)
–0.5 (–0.019)
+0.5 (+0.019)
–0.5 (–0.019)
mm (inch)
Ø 20…70
(Ø 0.79…2.75)
~
~ 6.1)
155 (
mm (inch)