Deltabar S
70
Hauser
PMD75
This overview does not mark options which are mutually exclusive.
10
Approval:
A
For non-hazardous areas
1
ATEX II 1/2 G
Ex ia IIC T6
6
ATEX II 1/2 G
Ex ia IIC T6, overspill protection WHG
2
ATEX II 1/2 D
4
ATEX II 1/3 D
8
ATEX II 1 GD
Ex ia IIC T6
3
ATEX II 1/2 GD
Ex ia IIC T6
5
ATEX II 2 G
Ex d IIC T6
7
ATEX II 3 G
Ex nA II T6
S
FM
IS, Class I, II, III Division 1, Groups A – G; NI Class I Division 2, Groups A – D; AEx ia
T
FM
XP, Class I Division 1, Groups A – D; AEx d
Q
FM
DIP, Class II, III Division 1, Groups E – G
R
FM
NI, Class I, Division 2, Groups A – D
U
CSA
IS, Class I, II, III Division 1, Groups A – G; Class I Division 2, Groups A – D, Ex ia
V
CSA
XP, Class I Division 1, Groups B – D; Ex d
W
CSA
Class II, III Division 1, Groups E – G (Dust-Ex)
G
NEPSI
Exd IIC T6
H
NEPSI
Ex ia IIC T6
I
IECEx Zone 0/1 Ex ia IIC T6
B
Combined certificates: ATEX II 1/2 G
Ex ia IIC T6 + II G Ex d IIC T6
C
Combined certificates: FM
IS and XP Class I Division 1, Groups A – D
D
Combined certificates: CSA
IS and XP Class I Division 1, Groups A – D
E
Combined certificates: FM/CSA
IS and XP Class I Division 1, Groups A – D
F
Combined certificates: ATEX II Ex ia / Ex d + FM/CSA IS + XP; ATEX II 1/2G Ex ia IIC T6+; ATEX II 2G Ex d IIC T6+;
FM/CSA IS + XP Cl.I Div.1 Gr.A-D
20
Output; Operation:
A
4...20 mA HART, SIL operation outside, LCD (
see Fig.
➀
,
n
)
B
4...20 mA HART, SIL operation inside, LCD (
see Fig.
➀
,
o
)
C
4...20 mA HART, SIL operation inside (
see Fig.
o
)
M
PROFIBUS PA, operation outside, LCD (
see Fig.
➀
,
n
)
N
PROFIBUS PA, operation inside, LCD (
see Fig.
➀
,
o
)
O
PROFIBUS PA, operation inside (
see Fig.
o
)
P
FOUNDATION Fieldbus, operation outside, LCD (
see Fig.
➀
,
n
)
Q
FOUNDATION Fieldbus, operation inside, LCD (
see Fig.
➀
,
o
)
R
FOUNDATION Fieldbus, operation inside (
see Fig.
o
)
30
Housing; Cable entry, Protection:
A
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Gland M 20x1.5
B
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Thread G 1/2
C
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Thread 1/2 NPT
D
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, M12x1 PA plug
E
Aluminium T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, 7/8" FF plug
F
Aluminium T14 housing, optional display on the side, IP 65/NEMA 4X, Han7D plug, 90°
J
Aluminium T15 housing, optional display on the top, IP 66/67/NEMA 4X/ 6P, Gland M 20x1.5
K
Aluminium T15 housing, optional display on the top, IP 66/67/NEMA 4X/ 6P, Thread G 1/2
L
Aluminium T15 housing, optional display on the top, IP 66/67/NEMA 4X/ 6P, Thread 1/2 NPT
M
Aluminium T15 housing, optional display on the top, IP 66/67/NEMA 4X/ 6P, M 12x1 PA plug
N
Aluminium T15 housing, optional display on the top, IP 66/67/NEMA 4X/ 6P, 7/8" FF plug
P
Aluminium T15 housing, optional display on the top, IP 65/NEMA 4X, Han7D plug, 90°
1
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Gland M 20x1.5
2
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Thread G 1/2
3
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, Thread 1/2 NPT
4
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, M 12x1 PA plug
5
AISI 316L T14 housing, optional display on the side, IP 66/67/NEMA 4X/ 6P, 7/8" FF plug
6
AISI 316L T14 housing, optional display on the side, IP 65/NEMA 4X, Han7D plug, 90°
R
T17 316L Hygiene IP66/68 NEMA6P; M20 gland, T17 = side cover
S
T17 316L Hygiene IP66/68 NEMA6P; G1/2 thread, T17 = side cover
T
T17 316L Hygiene IP66/68 NEMA6P; NPT1/2 thread, T17 = side cover
U
T17 316L Hygiene IP66/68 NEMA6P; M12 plug, T17 = side cover
V
T17 316L Hygiene IP66/68 NEMA6P; 7/8" plug, T17 = side cover
Z
Housing: see additional specifications
E
+
–
m
➂
2
1
PC
n
T14
T15
+ –
T17