Operation
Fieldgate FXA42
82
Hauser
Digital inputs settings
In this section the user may configure the settings for each digital input. The following
settings are available:
Settings
Description
Identifier
The label name of the input.
Description
A text describing the input's function.
Counter settings
In this section the user may configure the settings for each counter. The following settings
are available:
Settings
Description
Identifier
The label name of the counter.
Description
A text describing the counter's function.
Scaling unit
The counter's measurement unit.
Unit per pulse
Scaling factor of the counter.
Pulse counter
This setting defines the operational mode of the counter. The mode options are turned off,
counting upwards, or counting downwards.
Counter start value This is the value that the counter has each time it is reset.
Hold time
The hold time defines the minimum time that must elapse between 2 consecutive counting
events so that they are registered.
8.4.10 Data transmission and data logging
This page is used to configure which data will be transmitted via FIS or the other
communication methods, and which data should be logged internally. It is also possible to
set time intervals at which the data should be transmitted or logged. Data is internally
logged or recorded. Recorded data is communicated via all the enabled communication
methods.