Fieldgate FXA720
12 Appendix
Hauser
57
12.2 XML data elements
XML Bedeutung
" <?xml version=""1.0"" encoding=""ISO-8859-1"" ?>
Introduction
- <fieldgate>
Start: Fieldgate data
<timezone>+270</timezone>
Time offset to UTC im minutes
<REVISION>'00000'</REVISION>
XML revision
<DEVICE_NAME>FXA720Testcenter1</DEVICE_NAME>
Fieldgate Tag
<PB_SERIAL_NUMBER>88001124038</PB_SERIAL_NUMBER>
Fieldgate Serial No.
<PB_DEV_ID>FXA_720_DP_03</PB_DEV_ID>
Fieldgate Type Information
- <CHANNELS>
Start: PROFIBUS channel data
" - <CHANNEL no=""1"">"
Start: PROFIBUS channel No. 1
- <DEVICES>
Start: PROFIBUS devices
" - <DEVICE id=""7BFFFF0108D"">"
Start: PROFIBUS device
- <PHYSICAL_BLOCKS>
Start: physical blocks
- <PHYSICAL_BLOCK>
Start: physical block
<DEVICEADDRESS>19</DEVICEADDRESS>
PROFIBUS device address
<DEVICEID>7BFFFF0108D</DEVICEID>
Device ID
<MANUFACTURER>Hauser</MANUFACTURER>
Device manufacturer
<DEVICETAG>LICSA0100_10</DEVICETAG>
Device tag
<DEVICETYPE>FMR 2XX</DEVICETYPE>
Device type
<HWREV>2.01</HWREV>
Device hardware revision
<SWREV>01.01.02</SWREV>
Device software revision
<STATESIGN>OK</STATESIGN>
Device status
</PHYSICAL_BLOCK>
End: physical block
</PHYSICAL_BLOCKS>
End: physical blocks
- <FUNCTION_BLOCKS>
Start: function blocks
" - <FUNCTION_BLOCK type=""fb_input_analog"">"
Start: function block
<TAG>FB0011_fb_input_analog</TAG>
Point name
<LIMITSIGN>LO</LIMITSIGN>
Limit status (HH, HI, OK, LO, LL)
<OUT>0.818859</OUT>
Current value
<STAMP_DATE_VAL>20070621</STAMP_DATE_VAL>
Date stamp of current value
<STAMP_TIME_VAL>170445</STAMP_TIME_VAL>
Time stamp of current value
<STAMP_DATE_LVL>20070619</STAMP_DATE_LVL>
Date stamp of limit status
<STAMP_TIME_LVL>231534</STAMP_TIME_LVL>
Time stamp of limit status
<STATESIGN>OK</STATESIGN>
Block status (OK, UNC, BAD, N.A.)
<UNITSTRING>m</UNITSTRING>
Engineering unit
<HH>4</HH>
Limit value: high high
<HI>2.00</HI>
Limit value: high
<LO>1.00</LO>
Limit value: low
<LL />
Limit value: low low
<MAXDESC>5.00</MAXDESC>
Range max
<MINDESC>0</MINDESC>
Range min
<T1CH>Watertank #1</T1CH>
Value description (first line)
<T2CH />
Value description (second line)
</FUNCTION_BLOCK>
End: function block
</FUNCTION_BLOCKS>
End: function blocks
+ <TRANSDUCER_BLOCKS>
Start: transducer blocks …
</DEVICE>
End: device
" + <DEVICE id=""6601AE01020"">
"Next device …
" + <DEVICE id=""7A001F02000"">
"Next device …
</DEVICES>
End: devices
</CHANNEL>
End: PROFIBUS channel
" + <CHANNEL no=""2"">"
Start: PROFIBUS channel No. 2
" + <CHANNEL no=""3"">"
Start: PROFIBUS channel No. 3
</CHANNELS>
End: PROFIBUS channel data
</fieldgate>
End: Fieldgate data