Proline Promag 51
Installation
Hauser
27
Panel installation
1.
Prepare the opening in the panel as illustrated in the graphic.
2.
Slide the housing into the opening in the panel from the front.
3.
Screw the fasteners onto the wall-mount housing.
4.
Place the threaded rods in the fasteners and screw them down until
the housing is seated tightly against the panel. Afterwards, tighten the locking nuts.
Additional support is not necessary.
a0001131
Fig. 24:
Panel Installation (wall-mount housing)
Pipe mounting
The assembly should be performed by following the instructions in the graphic.
"
Caution!
If the device is mounted to a warm pipe, make certain that the housing temperature does not
55 °C (+131 °F), which is the maximum permissible temperature.
a0001132
Fig. 25:
Pipe mounting (wall-mount housing)
245 (9.65)
~110 (~4.33)
210 (8.27)
+0.5 (+0.019)
–0.5 (–0.019)
+0.5 (+0.019)
–0.5 (–0.019)
mm (inch)
Ø 20…70
(Ø 0.79…2.75)
~
~ 6.1)
155 (
mm (inch)