Identification
Proline Promag 51
8
Hauser
A0011329-en
Fig. 2:
Additional nameplate for Promag 51 measuring devices subject to legal metrological control (example)
1
Electromagnetic / mechanical ambient class
2
Permanent flowrate Q3
3
Permanent flowrate ratio Q3/Q1
4
Permitted fluid temperature range
5
Permitted operating temperature range
6
Information on pulse value
7
Conformity identification with CE-M mark, year number, notified body and number of EC type-examination
certificate
2.1.2
Nameplate of the sensor
A0004374
Fig. 3:
Nameplate specifications for the "Promag" sensor (example)
1
Ordering code/serial number: See the specifications on the order confirmation for the meanings of the individual
letters and digits.
2
Calibration factor: 0.5328 / zero point: -5
3
Nominal diameter: DN 100 / pressure rating: EN (DIN) 16 bar
4
Fluid temperature range
5
Lining material: PTFE, measuring electrodes: stainless steel 1.4435/316L
6
Reserved for information on special products
7
Ambient temperature range
8
Reference to Operating Instructions
9
Reserved for additional information on device version (approvals, certificates)
10
See "Maximum measured error"
11
Additional information (examples):
– EPD/MSU: with Empty Pipe Detection electrode
– R/B: with reference electrode
12
Degree of protection
13
Flow direction
340026
–
0000P
AA
Promag 51P DN100
1
2
5
3
1259 DE–07–MI001–PTB014
M09
4
6
7
E2/M2
Q3:
250 m³/h
Q3/Q1:
160
0…+30 °C
–40…+55 °C
Environmental Class:
Pulse Value
10 dm³
Medium Temperature:
Ambient Temperature:
-20°C (-4°F)<Tamb<+60°C (+140°F)
NEMA/Type4X
50PXX-XXXXXXXXXXXX
1.0000/0000
–10
...150°C/+14 ...300°F
°C
°F
PFA
12345678901 RY
ABCDEFGHJKLMNPQRST
DN100 DIN EN PN40
/
pnom =PS= 40bar
EPD/MSÜ, R/B
TM:
Order Code:
Materials:
K-factor:
Ser.No.:
TAG No.:
PROMAG P
1
2
3
7
13
12
1.4435/316L
Electrodes:
0.2% CAL
4
5
6
10
11
i
9
8
IP67
2007
N12895