Installation instructions

Preferably mount the cleaning unit close to the measuring point.

a0011385

Fig. 3:  Cleaning unit on tubular frame supplied

1

Cleaning unit

2

Tubular frame (mounted at factory)

3

Screws for securing to floor (not part of scope of delivery)

You have the following installation options: 

1.

Secure the unit mounted on the tubular frame to the floor (

å

3).

The required fastening material does not form part of the scope of delivery!

2.

Position the unit mounted on the tubular frame on the railing or an upright post and secure the 
tubular frame to the railing/post with a hose clip (not supplied).

3.4

Post-installation check

• After mounting, check all the connections to ensure they are secure and leak-tight.
• Check all cables and hoses for damage.
• Check whether the cables are routed such that they are free from electromagnetic interference 

influences.

Summary of Contents for ISEmax

Page 1: ...BA438C 07 EN 13 11 71144929 Operating Instructions ISEmax compressed air cleaning unit 230V AC Order No 71072583 ...

Page 2: ...Overview a0016120 Abb 1 Cleaning unit 1 Pump 2 Housing 3 Suction side with air filter 4 Terminal strip with fuse 5 Compressed air supply to the sensor 6 Tubular frame part of scope of delivery ...

Page 3: ...provals 6 3 Installation 6 3 1 Incoming acceptance transport storage 6 3 2 Installation conditions 8 3 3 Installation instructions 9 3 4 Post installation check 10 4 Wiring 10 4 1 Electrical connection to the transmitter 10 4 2 Post connection check 11 5 Commissioning 11 5 1 Function check 11 5 2 Switching on the unit 12 6 Maintenance 12 6 1 Maintenance schedule 12 6 2 Replacing the seal lip 13 7 ...

Page 4: ...to them Before commissioning the entire measuring point check all the connections Ensure that electrical cables and hose connections are not damaged Do not operate damaged products and secure them against unintentional commissioning Mark the damaged product as being defective Measuring point faults may only be rectified by authorized and specially trained personnel If faults can not be rectified t...

Page 5: ...ury WARNING Cause consequences Consequences if safety message is not heeded Corrective action This symbol alerts you to a dangerous situation Failure to avoid the situation can result in a fatal or serious injury CAUTION Cause consequences Consequences if safety message is not heeded Corrective action This symbol alerts you to a dangerous situation Failure to avoid this situation can result in min...

Page 6: ...r No 71072583 2 2 Scope of delivery The scope of delivery comprises 1 complete cleaning unit 1 set of Operating Instructions BA438C 07 DE 1 set of Operating Instructions BA438C 07 EN If you have any questions please contact your supplier or your local sales center 2 3 Certificates and approvals Declaration of conformity The product meets the requirements of the harmonized European standards It thu...

Page 7: ...e supplier about damage to the contents Keep the damaged products until the matter has been settled Check that the order is complete and agrees with your shipping documents The packaging material used to store or to transport the product must provide shock protection and humidity protection The original packaging offers the best protection Also keep to the approved ambient conditions see Technical...

Page 8: ...Installation 8 Endress Hauser 3 2 Installation conditions a0011377 Fig 2 Dimensions ...

Page 9: ...the unit mounted on the tubular frame to the floor å 3 The required fastening material does not form part of the scope of delivery 2 Position the unit mounted on the tubular frame on the railing or an upright post and secure the tubular frame to the railing post with a hose clip not supplied 3 4 Post installation check After mounting check all the connections to ensure they are secure and leak tig...

Page 10: ... to beginning any wiring work make sure voltage is not applied to any of the cables 4 1 Electrical connection to the transmitter NOTICE Usage of impermissible cable diameter Losing the protection class IP65 Use a cable with a diameter of 6 12 mm 0 24 0 47 for Pg 13 5 cable gland Use a cable with a diameter of 13 18 mm 0 51 0 71 for Pg 21 cable gland designated for mains Connect the cleaning unit t...

Page 11: ...ICE Damage to property because of not designated use The device is designated for interval operation i e maximum 3 minutes cleaning break of at least six times the cleaning time The device may not start up against a pressure load and may not be subject to pressure when at a standstill Use the unit to transport air only The cleaning unit should never be used to transport liquids or aggressive and o...

Page 12: ...system or on the process itself For your own safety only use genuine accessories With genuine parts the function accuracy and reliability are also ensured after maintenance work 6 1 Maintenance schedule As the only wear part the seal lip of the ribbed cover has to be replaced after an extended service life You know the seal lip has to be replaced if the delivery rate drops noticeably 6 2 Replacing...

Page 13: ...retension should cause it to fit properly in the cylinder 2 Position the spacer on the connecting rod disk Make sure it is positioned correctly in the corresponding recesses 3 Check the seal item 2 of the ribbed cover and replace it if necessary 4 Fit the intermediate plate in the ribbed cover Make sure it is seated correctly outline of thrust washer and outline of ribbed cover for bottom and top ...

Page 14: ...when using Pg 13 5 cable gland 13 to 18 mm 0 51 to 0 71 when using Pg 21 cable gland designated for mains 8 1 4 Electrical fuse of the pump 2 0A slow blow 8 2 Performance characteristics 8 2 1 Delivery rate 50 l min 13 2 gal min at atmospheric pressure 8 2 2 Utilization interval Max 3 minutes cleaning break of at least six times the cleaning time 8 3 Environment 8 3 1 Ambient temperature range 10 ...

Page 15: ... 15 I Icons 5 Incoming acceptance 6 Installation 4 6 8 Check 10 Installation instructions 9 M Maintenance 12 Maintenance schedule 12 N Nameplate 6 O Operation 4 Operational safety 4 Ordering 6 Overheat control 15 P Performance characteristics 15 Post connection check 11 Power consumption 15 Product structure 6 R Replacing the seal lip 13 Return 4 S Safety icons 5 Scope of delivery 6 Spare parts 14...

Page 16: ...BA438C 07 EN 13 11 FM SGML 6 0 ...

Reviews: