3.5
Cleaning of the probe
3.5.1
Cleaning of the probe in the tank
Installation close to tank wall
Installation in the center of the tank
• By installing the probe close to the tank wall,
the cleaning effect is improved in cases where
a spray ball is used. The cleaning jet is
deflected against the tank wall and onto the
probe. This means that those parts of the
probe are cleaned which would normally not
be reached by the spray ball jet. If the probe is
positioned in this way, only one spray ball is
needed.
L00-FMP43xxx-17-00-00-xx-003
• If the probe is mounted in the center of the
tank, it may be necessary to use a second spray
ball. The spray balls should then be mounted
to the left and right of the probe.
L00-FMP43xxx-17-00-00-xx-004