Float Gauge LTC2230/LTC2240
6.2
Failure Causes and Countermeasures
No.
Specification
No.
Specification
81
56004495
Steel front cover assy, low P. L
88
56004487
Rulon metal
70106496
U-rubber, LT22 indicator cover
91
52017003
Float FL140, SUS316, 2.1kg with ring
82
56004462
Packing, rear cover, hiker cork
52017004
Float FL140, SUS316, 2.4kg with ring
56004462
Packing, rear cover, cork
52017001
Float FL140, PVC, 2.4kg with ring
83
56004318
Dial plate, 2.5m,
52017002
Float FL140, PVC, 2.1kg with ring
56004316
Dial plate, 10m
56004369
Float LF140, 316, 2.1kg, w/o ring
56004320
Dial plate, 5m
56004370
Float LF140, 316, 2.4kg, w/o ring
56004391
Index Alu
56004367
Float LF140, PVC, 2.1kg, w/o ring
84
56004529
Wire drum, gear
56004368
Float LF140, PVC, 2.4kg, w/o ring
85
56004302
Conster drum
92
56004413
Measuring wire 0.8mm, 10m
52015582
Conster spring, 5m
56004416
Measuring wire 0.8mm, 5m
017860-5033
Conster spring, 10m
93
56004405
Lifting ring float 140D
86
56004304
Conster reeling drum
94
56004925
Wire sleeve 0.8mm
87
70106001
Main shaft assembly
Symptom
Possible Causes
Countermeasures
Indicator does not move.
1. Severed measuring tape
2. Conster broken or damaged
3. Sunken float
1. Replace measuring wire
2. Replace conster
3. Replace float
Error value of indicator arise.
1. Conster worn or damaged
2. Indicator loose
1. Replace conster
2. Remove the indicator cover and check the needle.
There is difference between the
measuring value of liquid level and the
indicated value on the display.
1. LTC malfunction or failure
2. No LTC defects found
1. Inspect and/or perform the countermeasures described above.
2. Measurement value inaccurate due to accumulated sludge,
improper calculation, etc..
6 Troubleshooting