Micropilot FMR56, FMR57 FOUNDATION Fieldbus
Integration into a FOUNDATION Fieldbus network
Hauser
71
9.6.8
Service Information Transducer Block
The parameters of the
Service Information
Transducer Block can only be operated by
authorized Hauser service personnel.
9.6.9
Advanced Diagnostics Transducer Block
The parameters of the
Advanced Diagnostics Transducer Block
are described in
GP01017F: "Micropilot FMR5x - Description of Device Parameters - FOUNDATION
Fieldbus"
Name
Label
Index Data type Size (Bytes) Storage Class Write access MODE_BLK
assign_diag_signal_ad1
Assign diagnostic signal 1
15
ENUM16 2
Static
Maintenance OOS
link_ad1_to
Link AD1 to
16
ENUM16 2
Static
Maintenance OOS
linking_logic_ad1
Linking logic AD1
17
ENUM16 2
Static
Maintenance OOS
sample_time_ad1
Sample time 1
18
UINT16
2
Static
Maintenance OOS
calc_type_ad1
Calculation type 1
19
ENUM16 2
Static
Maintenance OOS
check_mode_ad1
Check mode 1
20
ENUM16 2
Static
Maintenance OOS
calculation_unit_ad1
Calculation unit 1
21
ENUM16 2
Static
Operator
OOS
upper_limit_ad1
Upper limit 1
22
FLOAT
4
Static
Maintenance OOS
lower_limit_ad1
Lower limit 1
23
FLOAT
4
Static
Maintenance OOS
hysteresis_ad1
Hysteresis 1
24
FLOAT
4
Static
Maintenance OOS
max_value_ad1
Maximum value 1
25
FLOAT
4
Dynamic
min_value_ad1
Minimum value 1
26
FLOAT
4
Dynamic
reset_min_max_ad1
Reset min./max. 1
27
ENUM16 2
Static
Maintenance AUTO
assign_status_sig_ad1
Assign status signal to AD event 1
28
ENUM16 2
Static
Maintenance OOS
assign_event_behaviour_ad1
Assign event behaviourn 1
29
ENUM16 2
Static
Maintenance OOS
alarm_delay_ad1
Alarm delay
30
FLOAT
4
Static
Maintenance OOS
assign_diag_ signal_ad2
Assign diagnostic signal 2
31
ENUM16 2
Static
Maintenance OOS
link_ad2_to
Link AD2 to
32
ENUM16 2
Static
Maintenance OOS
linking_logic_ad2
Linking logic AD2
33
ENUM16 2
Static
Maintenance OOS
sample_time_ad2
Sample time 2
34
UINT16
2
Static
Maintenance OOS
calc_type_ad2
Calculation type 2
35
ENUM16 2
Static
Maintenance OOS
check_mode_ad2
Check mode 2
36
ENUM16 2
Static
Maintenance OOS
calculation_unit_ad2
Calculation unit 2
37
ENUM16 2
Static
Operator
OOS
upper_limit_ad2
Upper limit 2
38
FLOAT
4
Static
Maintenance OOS
lower_limit_ad2
Lower limit 2
39
FLOAT
4
Static
Maintenance OOS
hysteresis_ad2
Hysteresis 2
40
FLOAT
4
Static
Maintenance OOS
max_value_ad2
Maximum value 2
41
FLOAT
4
Dynamic
min_value_ad2
Minimum value 2
42
FLOAT
4
Dynamic
reset_min_max_ad2
Reset min./max. 2
43
ENUM16 2
Static
Maintenance AUTO
assign_status_sig_ad2
Assign status signal to AD event 2
44
ENUM16 2
Static
Maintenance OOS
assign_event_behaviour_ad2
Assign event behaviour 2
45
ENUM16 2
Static
Maintenance OOS
alarm_delay_ad2
Alarm delay 2
46
FLOAT
4
Static
Maintenance OOS