Integration into a FOUNDATION Fieldbus network
Micropilot FMR56, FMR57 FOUNDATION Fieldbus
66
Hauser
Name
Label
Index
Data type
Size (Bytes)
Storage Class
Write access
MODE_BLK
calculated_dc_value_ee
Calculated DC value
17
FLOAT
4
Dynamic
Production
AUTO
liquid_filling_speed_range
Max. filling speed liquid
18
ENUM16
2
Static
Maintenance
OOS
liquid_draining_speed_ran
ge
Max. draining speed liquid
19
ENUM16
2
Static
Maintenance
OOS
advanced_process_conditio
ns
Advanced process
conditions
20
ENUM16
2
Static
Maintenance
OOS
level_unit
Level unit
21
ENUM16
2
Static
Maintenance
OOS
blocking_distance
Blocking distance
22
FLOAT
4
Static
Maintenance
OOS
level_correction
Level correction
23
FLOAT
4
Static
Maintenance
OOS
empry_distance
Tank/silo height
24
FLOAT
4
Static
Maintenance
OOS
linearization_type
Linearization type
25
ENUM16
2
Static
Maintenance
OOS
unit_after_linearization
Unit after linearization
26
ENUM16
2
Static
Maintenance
OOS
free_text
Free text
27
STRING
Static
Maintenance
AUTO
maximum_value
Maximum value
28
FLOAT
4
Static
Maintenance
OOS
level_linearized_ds
Level linearized
29
Standard
5
Dynamic
diameter
Diameter
30
FLOAT
4
Static
Maintenance
OOS
intermediate_height
Intermediate height
31
FLOAT
4
Static
Maintenance
OOS
table_number
Table number
32
UINT8
1
Static
Maintenance
OOS
table_mode
Table mode
33
ENUM16
2
Static
Maintenance
OOS
activate_table
Tabelle aktivieren
34
ENUM16
2
Static
Maintenance
OOS
custom_table_sel_level
Level
67
FLOAT
4
Static
Maintenance
OOS
custom_table_sel_value
Customer value
68
FLOAT
4
Static
Maintenance
OOS
level_semiautomatic
Level
69
FLOAT
4
Dynamic
output_echo_lost
Output echo lost
70
ENUM16
2
Static
Maintenance
OOS
value_echo_lost
Value echo lost
71
FLOAT
4
Static
Maintenance
OOS
ramp_at_echo_lost
Ramp at echo lost
72
FLOAT
4
Static
Maintenance
OOS
switch_output_function
Switch output function
73
ENUM16
2
Static
Maintenance
OOS
assign_status
Assign status
74
ENUM16
2
Static
Maintenance
OOS
assign_limit
Assign limit
75
ENUM16
2
Static
Maintenance
OOS
assign_diag_behavior
Assign diagnostic behavior
76
ENUM16
2
Static
Maintenance
OOS
switch_on_value
Switch-on value
77
FLOAT
4
Static
Maintenance
OOS
switch_on_delay
Switch-on delay
78
FLOAT
4
Static
Maintenance
OOS
switch_off_value
Switch-off value
79
FLOAT
4
Static
Maintenance
OOS
switch_off_delay
Switch-off delay
80
FLOAT
4
Static
Maintenance
OOS
switch_output_failure_mod
e
Failure mode
81
ENUM16
2
Static
Maintenance
OOS
switch_status
Switch status
82
ENUM16
2
Dynamic
invert_output_signal
Invert output signal
83
ENUM16
2
Static
Maintenance
OOS
9.6.3
Display Transducer Block
Name
Label
Index
Data type
Size (Bytes)
Storage Class
Write access
MODE_BLK
locking_status_display
Locking status
15
ENUM16
2
Dynamic
access_status_display
Access status display
16
ENUM16
2
Dynamic
Summary of Contents for Micropilot FMR56
Page 197: ......