Commissioning
Micropilot M FMR244 with FOUNDATION Fieldbus
64
Hauser
6.4.2
Envelope curve with VU 331
After the basic setup, an evaluation of the measurement with the aid of the envelope curve
("
envelope curve
"
(0E)
function group) is recommended.
Function "plot settings" (0E1)
Select which information will be displayed in the LCD:
•
envelope curve
• env.curve+FAC (on FAC see BA 221F)
• env.curve+cust.map (i.e. customer tank map is also displayed)
Function "recording curve" (0E2)
This function defines whether the envelope curve is read as a
•
single curve
or
• cyclic.
!
Note!
If the cyclical envelope curve is active in the display, the measured value is refreshed in a slower
cycle time. It is therefore recommended to exit the envelope curve display after optimising the
measuring point.
!
Note!
An
orientation
of the Micropilot can help to optimise measurement in applications with very weak
level echos or strong interference echos by increasing the useful echo/reducing the interference
echo (see "Orientation of the Micropilot" on Page 81).
When using the Wave Guide antenna:
No
orientation is required!
⇒
E HAUSER
E
+
–
⇒
E HAUSER
E
+
–