Proline Cubemass C 500
100
Hauser
Ex ec
Category
Type of protection
Transmitter
Sensor
II3G
Ex ec IIC T5…T4 Gc
Ex ec IIC T5…T1 Gc
C
CSA
US
Currently, the following versions for use in hazardous areas are available:
IS (Ex i) and XP (Ex d)
Transmitter
Sensor
Class I, III, III Division 1 Groups A-G
NI (Ex nA)
Transmitter
Sensor
Class I Division 2 Groups ABCD
Ex de
Transmitter
Sensor
Class I, Zone 1 AEx/ Ex de ia IIC T6…T4 Gb
Class I, Zone 1 AEx/ Ex ia IIC T6…T1 Ga/Gb
Class I, Zone 1 AEx/ Ex de ia IIC T6…T4 Gb
Class I, Zone 1 AEx/ Ex ia IIC T6…T1 Gb
Ex d
Transmitter
Sensor
Class I, Zone 1 AEx/ Ex d ia IIC T6…T4 Gb
Class I, Zone 1 AEx/ Ex ia IIC T6…T1 Ga/Gb
Class I, Zone 1 AEx/ Ex d ia IIC T6…T4 Gb
Class I, Zone 1 AEx/ Ex ia IIC T6…T1 Gb
Ex nA
Transmitter
Sensor
Class I, Zone 2 AEx/ Ex nA IIC T5...T4 Gc
Class I, Zone 2 AEx/ Ex nA IIC T5...T1 Gc
Ex tb
Transmitter
Sensor
Zone 21 AEx/ Ex tb IIIC T85°C Db
Zone 21 AEx/ Ex ia tb IIIC T** °C Db
Pharmaceutical compatibility
• FDA
• USP Class VI
• TSE/BSE Certificate of Suitability
Functional safety
The measuring device can be used for flow monitoring systems (min., max., range) up to SIL 2
(single-channel architecture; order code for "Additional approval", option LA) and SIL 3
(multichannel architecture with homogeneous redundancy) and is independently evaluated and
certified by the TÜV in accordance with IEC 61508.