• The device can be connected to the Hauser FXA291 service tool when area is 

known to be non hazardous. Refer to the Operating Instructions.

• Basic specification, Position 3 (Output) = A, B, C, G

– When the intrinsically safe Ex ia circuits of the device are connected to certified 

intrinsically safe circuits of Category Ex ib for Equipment Groups IIC or IIB, the type of 

protection changes to Ex ib IIC or Ex ib IIB.

– When the intrinsically safe Ex ia circuits of the device are connected to certified 

intrinsically safe circuits of Category Ex ia for Equipment Group IIB, the type of 

protection changes from Ex iaIIC to Ex ia IIB. 

Potential equalization 

Integrate the device into the local potential equalization. If the ground connection has been 

established via the pipe as specified, it is also possible to integrate the sensor into the 

potential equalization system via the pipe.

Safety instructions: 

Zone 0

In the event of potentially explosive vapour/air mixtures, only operate the device under 

atmospheric conditions. 

• Temperature: –20 to + 60°C

• Pressure: 80 to 110 kPA (0.8 to 1.1 bar) 

• Air with normal oxygen content, usually 21 % (V/V)
If no potentially explosive mixtures are present, or if additional protective measures have 

been taken according to EN 1127-1, the device may also be operated under non-

atmospheric conditions in accordance with the manufacturer's specifications.

Basic specification, Position 1, 2 (Approval): N4

Install the transmitter electronics in Zone 1. The device can, however, be used in the 

measuring pipe in Zone 0.

Safety instructions: 

Zone 21

• To ensure dust-tightness, securely seal the transmitter housing and cable entries.

• Only open the transmitter housing briefly, ensuring that no dust or moisture enters the 

housing.

• Only use certified cable entries or sealing plugs. The metal sealing plugs supplied meet the 

requirements.

Summary of Contents for Proline Promass 200

Page 1: ...ine Promass 200 NEPSI Zone 1 Zone 0 1 Zone 21 Ex i version en Document XA00156D Safety instructions for electrical apparatus for explosion hazardous areas classified according to National Supervision...

Page 2: ...Products Solutions Services...

Page 3: ...certificates of conformity 4 Extended order code 4 Safety instructions General 6 Safety instructions Installation 6 Safety instructions Zone 0 7 Safety instructions Zone 21 7 Temperature tables Compa...

Page 4: ...ty GB3836 1 4 2010 GB12476 1 2000 Certification numbers GYJ11 1524 Referential certification numbers GYJ11 1519U GYJ11 1520U GYJ11 1521U GYJ11 1522U GYJ11 1523U Inspection body NEPSI National Supervis...

Page 5: ...ial wetted parts inspection certificate More detailed information about the device is provided in the following tables These tables describe the individual positions and IDs in the extended order code...

Page 6: ...must be carried out by staff authorized to perform such work by Endress Hauser Observe all the technical data of the device see nameplate When using in hybrid mixtures gas and dust occurring simultane...

Page 7: ...ntegrate the sensor into the potential equalization system via the pipe Safety instructions Zone 0 In the event of potentially explosive vapour air mixtures only operate the device under atmospheric c...

Page 8: ...on with overvoltage protection OVP in connection with temperature class T5 T6 Ta Ta 2 C 2 For specified sensors with a maximal medium temperature Tm 200 C Tm 170 C 3 For specified sensors with a maxim...

Page 9: ...h a maximal medium temperature Tm 200 C Tm 200 C Output basic specification position 3 G Approval Basic specification positions 1 2 NEPSI NF N4 Sensor type Ta C T6 85 C T5 100 C T4 135 C T3 200 C T2 3...

Page 10: ...he maximum surface temperature Procedure for determining the maximum surface temperature 1 Select the device Promass F 200 nominal diameter DN 25 and ambient temperature Ta 60 C in the associated temp...

Page 11: ...Impulse Frequency Switch output C 4 20 mA HART 4 20 mA G PROFIBUS PA Impulse Frequency Switch output Output Basic specification Position 3 Signal circuits Instrinsically save values Electric circuits...

Page 12: ...www addresses endress com...

Reviews: