• The device can be connected to the Hauser FXA291 service tool when area is
known to be non hazardous. Refer to the Operating Instructions.
• Basic specification, Position 3 (Output) = A, B, C, G
– When the intrinsically safe Ex ia circuits of the device are connected to certified
intrinsically safe circuits of Category Ex ib for Equipment Groups IIC or IIB, the type of
protection changes to Ex ib IIC or Ex ib IIB.
– When the intrinsically safe Ex ia circuits of the device are connected to certified
intrinsically safe circuits of Category Ex ia for Equipment Group IIB, the type of
protection changes from Ex iaIIC to Ex ia IIB.
Potential equalization
Integrate the device into the local potential equalization. If the ground connection has been
established via the pipe as specified, it is also possible to integrate the sensor into the
potential equalization system via the pipe.
Safety instructions:
Zone 0
In the event of potentially explosive vapour/air mixtures, only operate the device under
atmospheric conditions.
• Temperature: –20 to + 60°C
• Pressure: 80 to 110 kPA (0.8 to 1.1 bar)
• Air with normal oxygen content, usually 21 % (V/V)
If no potentially explosive mixtures are present, or if additional protective measures have
been taken according to EN 1127-1, the device may also be operated under non-
atmospheric conditions in accordance with the manufacturer's specifications.
Basic specification, Position 1, 2 (Approval): N4
Install the transmitter electronics in Zone 1. The device can, however, be used in the
measuring pipe in Zone 0.
Safety instructions:
Zone 21
• To ensure dust-tightness, securely seal the transmitter housing and cable entries.
• Only open the transmitter housing briefly, ensuring that no dust or moisture enters the
housing.
• Only use certified cable entries or sealing plugs. The metal sealing plugs supplied meet the
requirements.