5 Operation
Proline Promass 83 FOUNDATION Fieldbus
40
Hauser
Icons
The icons which appear in the field on the left make it easier to read and recognise measured varia-
bles, device status, and error messages.
Icon
Meaning
Icon
Meaning
S
System error
P
Process error
$
Fault message
(measuring is interrupted)
!
Notice message (measuring
continues despite the message)
Σ
1...n
Totalizer 1...n
AI 1 (...n)
Analog Input Function Block 1 (...n),
output value OUT
PID
PID Function Block:
A PID function block value as listed below is output, depending on the assignment of the lines in the
local display:
OUT value (= manipulated variable)
IN value (= control variable)
CAS_IN value (= external setpoint)
The messages listed below describe the status of the OUT value of the Analog Input Function Block and the value assi-
gned to the PID Function Block.
OK
Status = GOOD (valid)
UNC
Status = UNCERTAIN (conditionally valid)
BAD
Status = BAD (invalid)
Example:
OUT value of the Analog Input Function Block 1 with a GOOD status on the display
a0001183
Measuring mode;
STANDARD
a0001182
Measuring mode;
SYMMETRY (bidirectional)
a0001185
Counting mode, totalizer;
forward
a0001184
Counting mode, totalizer;
BALANCE (forward and reverse flow)
a0001186
Counting mode, totalizer;
reverse
a0001195
Mass flow
a0001188
Volume flow
a0001188
Corrected volume flow
a0001208
Reference density
a0001200
Fluid density
a0001207
Fluid temperature
a0001206
Active device operation via
FOUNDATION Fieldbus.
Summary of Contents for Proline Promass 83
Page 24: ...3 Installation Proline Promass 83 FOUNDATION Fieldbus 24 Endress Hauser ...
Page 34: ...4 Wiring Proline Promass 83 FOUNDATION Fieldbus 34 Endress Hauser ...
Page 64: ...6 Commissioning Proline Promass 83 FOUNDATION Fieldbus 64 Endress Hauser ...
Page 66: ...7 Maintenance Proline Promass 83 FOUNDATION Fieldbus 66 Endress Hauser ...
Page 90: ...9 Trouble shooting Proline Promass 83 FOUNDATION Fieldbus 90 Endress Hauser ...
Page 116: ...Index Proline Promass 83 FOUNDATION Fieldbus 116 Endress Hauser ...
Page 118: ...www endress com worldwide BA065D 06 en 12 04 50098623 FM SGML 6 0 ...