5. Set strapping band 1 to the desired position.
6. Push down the tensioning screw and tighten strapping band 1 so it cannot slip.
7. Strapping band 2: proceed as for strapping band 1 (steps 1 to 6).
8. Only slightly tighten strapping band 2 for final mounting. It must be possible to move
strapping band 2 for final alignment.
9. If necessary, shorten both strapping bands and trim the cut edges.
L
WARNING
Risk of injury!
‣
To avoid sharp edges, trim the cut edges after shortening the strapping bands. Wear
suitable gloves and protective goggles.
1
2
3
A0043373
8
Holder with strapping bands (medium nominal diameters), with hinged screw
1
Mounting bolts
2
Strapping band
3
Tensioning screw
1
2
3
A0044350
9
Holder with strapping bands (medium nominal diameters), without hinged screw
1
Mounting bolts
2
Strapping band
3
Tensioning screw