Installation
Proline Prosonic Flow P
30
Hauser
10. Insert the sensor cable into the sensor until the end stop.
A0043383
19
Mounting the sensor and connecting the sensor cable
The sensors can now be connected to the transmitter via the sensor cables and the
error message can be checked in the sensor check function. This completes the
mounting procedure.
• The visible measuring pipe surface must be clean (free from flaking paint and/or rust)
to ensure good acoustic contact.
• If the sensor is removed from the measuring pipe, it must be cleaned and new coupling
gel applied (if there is no coupling pad).
• On rough measuring pipe surfaces, the gaps in the rough surface must be filled with
sufficient amounts of coupling gel if the use of the coupling pad does not suffice
(installation quality check).
Installation for measurement via 2 traverses
Requirements
• The installation distance is known → 16
• Strapping bands are pre-assembled
Material
The following material is required for mounting:
• Two strapping bands incl. mounting bolts and centering plates where necessary (already
• A mounting rail to position the strapping bands:
• Short rail up to DN 200 (8")
• Long rail up to DN 600 (24")
• No rail > DN 600 (24"), as distance measured by sensor distance between the mounting
bolts
• Two mounting rail holders
• Two sensor holders
• Coupling medium (coupling pad or coupling gel) for an acoustic connection between the
sensor and pipe