Technical data
Teqwave H
88
Hauser
Languages
Can be operated in the following languages:
• Via local operation (transmitter with touch screen)
English, German, French, Spanish, Italian
• Via operating tool
English, German, French, Spanish, Italian
16.12 Certificates and approvals
CE mark
The device meets the legal requirements of the applicable EU Directives. These are listed in
the corresponding EU Declaration of Conformity along with the standards applied.
Hauser confirms successful testing of the device by affixing to it the CE mark.
Hygienic compatibility
• EHEDG Type EL Class I
• The EHEDG approval refers to the sensor.
• Confirmation by affixing the EHEDG symbol for sensors with the order code for
"Additional approval", option LT "EHEDG".
• To meet the requirements for EHEDG certification, the sensor must be connected with
process connections in accordance with the EHEDG position paper entitled "Easy
Cleanable Pipe Couplings and Process Connections" (
www.ehedg.org
).
• Food Contact Materials Regulation (EC) 1935/2004
• FDA: All wetted parts are in conformity with FDA requirements.
• Seals
• EPDM is not a suitable seal material for media with a fat content > 8 %.
• FDA-compliant seals: EPDM, FKM, VMQ.
• EHEDG-compliant seals: EPDM, FKM.
3-A approval is in preparation. Certificates that are currently valid are available in the
Download Area of the Hauser website:
• www.endress.com → Downloads
• Specify the following details in the search area: Approvals & certificates → Hygienic
compatibility
Additional certification
Tests and certificates
EN10204-3.1 material certificate, wetted parts
Other standards and
guidelines
• EN 60529
Degrees of protection provided by enclosures (IP code)
• EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory
use - general requirements
• IEC/EN 61326-2-3
Electromagnetic compatibility (EMC requirements)
• RoHS and IEC 63000
Restriction of hazardous substances in electric and electronic devices.
16.13 Application packages
Application packages are available for the device to expand the device functions,
depending on user needs. The application packages can be ordered with the device or
subsequently from Hauser. The Hauser sales organization will provide
detailed information on the appropriate order code. The product page of the