Technical data
Teqwave H
86
Hauser
16.9 Process
Medium temperature range
Sensor
0 to +120 °C (+32 to +248 °F)
Nominal pressure
Sensor
Max. 16 bar (232 psi) at 20 °C (68 °F)
Flow velocity
Max. 10 m/s (32.8 ft/s)
16.10 Mechanical construction
Design, dimensions
For the dimensions and installation lengths of the device, see the "Technical
Information" document, "Mechanical construction" section .
Weight
Transmitter
Transmitter with aluminum
housing
0.34 kg (0.8 lb)
Transmitter with stainless
steel housing
1.47 kg (3.24 lb)
Sensor
DN 25 mm (DIN)
Max. 2.42 kg (5.34 lb)
DN 1" (ANSI)
Max. 2.48 kg (5.47 lb)
The weight refers to the weight of a device with flanges. It can be lower than specified
depending on the process connection.
Materials
Transmitter housing
Aluminum transmitter housing, order code for "Transmitter housing", option A
Housing
Anodized aluminum
Window material
Glass
Terminal connection
Polybuteneterephthalate (PBT)
Ethernet interface
• Socket: ferrite
• Contact housing: thermoplastic
• Contacts: 100 % tin with nickel coating, gold-plated
Push-pull connection
• Socket: brass, nickel-plated
• Contact housing: polyetheretherketone (PEEK)
• Contacts: brass, gold-plated
Stainless steel transmitter housing, order code for "Transmitter housing", option B
Housing
Stainless steel 1.4301 (304)
Window material
Polycarbonate