M e r i d i a n I I U s e r M a n u a l
118
C H A P T E R T E N
119
M e r i d i a n I I U s e r M a n u a l
R E A R - P A N E L I / O
����������
����������������������������������
����������
���������
User Settings
There are user settings associated with the T1, J1, E1 and Composite Clock outputs. There are no
user settings for the optional Alarm Output. User settings are:
T1/J1:
Framing Mode, Alarm Mode, Line Build-Out
E1:
Framing Mode, Alarm Mode
Composite Clock: Line Code, Alarm Mode
You can view or change the user settings for each output by using the front-panel keypad/display (see
Chapter 3 - Front-Panel Kaypad and Display
) or by using the console commands
pluginopts
and
pluginoptsconfig
(see
Chapter 3 - Control and Status Commands
). Available selections for
each user setting are:
T1 Framing Mode:
Unframed, SF (D4) and ESF (CRC6)
T1 Alarm Mode:
N/A*, None, AIS, SSM
T1 Line Build-Out:
1-133 feet, 133-266 feet, 266-399 feet, 399-533 feet, 533-655 feet
J1 Framing Mode:
SF(D4), ESF(CRC6)
J1 Alarm Mode:
None, AIS
J1 Line Build-Out:
0-655 feet
E1 Framing Mode:
Unframed,FAS Double-Frame, CRC4 Multi-Frame
E1 Alarm Mode:
N/A*, None, AIS, SSM
Comp Clock Line Code:
AMI, AMI with 8kHz BPV, AMI with 8kHz BPV+400Hz non-BPV
Comp Clock Alarm Mode: N/A*, None, AIS
*Alarm Mode not applicable when unframed (all ones).
TELECOM CLOCK MODULE
Summary of Contents for Meridian II
Page 2: ......
Page 20: ...M e r i d i a n I I U s e r M a n u a l This page intentionally left blank...
Page 139: ...119 M e r i d i a n I I U s e r M a n u a l R E A R P A N E L I O...
Page 216: ...M e r i d i a n I I U s e r M a n u a l 196 A P P E N D I X J...
Page 235: ...215 M e r i d i a n I I U s e r M a n u a l S P E C I F I C AT I O N S...
Page 236: ...M e r i d i a n I I U s e r M a n u a l 216 A P P E N D I X K...
Page 239: ......