5. Mounting
CAUTION: Refer all servicing to qualified service personnel.
. Drill 4 holes on the wall to fix the mounting base.
CAUTION: • For safety, the structure wall that this unit is installed on should be strong enough to support
a minimum of 25kg.
• For safety, connect a Ass’y Dome Housing under 9kg to the nut.
. Insert the plastic anchors inside each hole.
3. Attach the mounting base by using the screws (PTS M6) and the plastic anchors on the wall.
4. Fix the BNC cable with the cable clamp within the mounting.
5. Close the mounting and tighten the screws.
NOTE:
You can prevent moisture from generating inside as sealing gaps between PGs and cables
completely.
Seal this using the Teflon tape
around a thread of a socket.
Wire colours according to EIA/TIA 56B
Pin
Colour
Ethernet
Connected
orange
Transmit Data +
yes
orange / white
Transmit Data –
yes
3
green
Receive Data +
yes
4
blue / white
not used –
–
5
blue
not used +
–
6
green / white
Receive Data –
yes
7
brown
not used +
–
brown / white
not used –
–
Cable assignment (network plug)