8
Detach the dome camera from the Easy Adaptor
Push the hook on the dome base and swing the dome base to counterclock wise. Then
detach the dome camera from the installed Easy Adaptor.
1
2
3
Open the dome cover
1. Insert wide side of Open Tool into the lock of Dome Cover.
2. Hold the Dome housing with one hand and turn the open tool until Dome Cover
is sufficiently open.
3. Once Dome Base and Dome Cover are detached, press the edge of Dome Cover
and pull it down with hands.
1
2
Pan & Tilt adjustments
1. Pan limit: Pan is limited to +/- 175°. Do NOT force to rotate the gimbal over the
limit to prevent from the internal damage.
2. Tilt limit: Tilt is limited to 25° min ~ 90° max. with reference to the ceiling when
the inclination of camera module is 0°, that is, the image is aligned horizontally.
3. Inclination limit (Horizontal image alignment): Inclination limited to +/- 175° max.