2.5 FLAME FAILURE DURING RUNNING STATUS (ONE TRIAL RECYCLING)
In case of flame failure in running status, the flame control unit make one trial restarting the unit.
If the reason of flame failure is confirmed, then the unit stops in lock-out mode, and the reset lamp becomes red.
2.6 RESET LAMP COLOR
WARNING
The reset button may have different colours:
•
light off: unit is in stand-by status, waiting for heating request.
•
steady orange light : the heater stops temporarily to allow H/T/ transformer cooling down and
automatically restarts when the time has passed
•
steady green light: unit is working normally (starting cycle or working cycle)
•
steady red light: the heater stops permanently in lock-out status and can restart only if reset button is
pressed.
Room thermostat
Reset Lamp
Photocell
Fuel Valve
Ignition Transformer
Burner Fan
TP 20 s
TS 5 s
90 s
!