ASSEMBLY AND USER MANUAL
Combi [6 | 12 | 16] & Combi 12 HT
www.energie.pt
11
5.2.4.
Unevenness
Under normal circumstances the total maximum gradient must always be less than 15 mts. However, there are
situations where it is not possible to respect these distances, in these cases you must consult our technical
department.
The aspiration piping must rise above the level of the panels, in the same way as the distribution shaft in order to
avoid the rapid siphon effect of the liquid at the time of the stoppage of the compressor.
5.2.5.
Standard Gap of the Panels
The position of the panels and the choice of the sides of the connections must be carried out so as to limit the length
of the piping and simplify the connections.
The panel gap is determined so as to facilitate its placement and the implementation of the connections between
piping, though due consideration must be given to:
✓
Minimum space between the panels on the connections’ side: 200mm (ideal space: 500mm).
✓
Space between the panels on the side opposite the connections: they should preferably not be
completely stuck together (preferably> 20mm)
Key:
A
Solar Panels
B
Distributor
C
Combi Block