Defrost
The thermostat automatically enter the Defrost Mode when the room temperature
drops below the defrost temperature.
The range is 7-17°C. The default is 7°C and is suit-
able for most applications.
of the thermostat. The system defaults to 0.5°C, meaning that when the tempera-
ture is set to 20°C, the thermostat will start heating at 19.5°C and stop at 20°C. If the
default value is 1° degree, start heating at 19°C, stop at 20°C.
The switching differential is settable between 0.5°C - 3°C .
Output Delay
To prevent rapid switching, an output delay can be entered. This can be set from
0-15 minutes. The default is 0, meaning no delay. This function helps to prevent
system “Short-cycling”.
Away
A preset temperature while away from the house. The range is 7-35°C, default is 7°C. To
change/set the temperature, follow these steps:
Press the icon and enter Feature Settings.
Find the “Away” option, press it and enter setting interface.
Use the icons to adjust the temperature.
Press the icon twice to save and return to main display.
01
02
03
04
Press the icon and enter Feature Settings.
Find the “Defrost” option, press it and enter setting interface.
Temperature Options.
Use the icons to adjust the temperature.
Press the icon twice to save and return to main display.
01
02
03
04
15