background image

Operating voltage / Power supply

85-230VAC, 50/60Hz

Standby power

< 1.0W

Rated Current / Relay

16A resistive load, 230V

Setting range, temperature

5-45°C

Floor limitation, temperature range

20-45°C

On/Off differential

±0.5°C

Humidity sensor, air

0-100%

Operating modes

Three programming modes:

Weekday/Weekend (5 + 2)

- edit/set 4 time periods per day

Seven day programming (7)

- edit/set 4 time periods per day

24 hours mode

- edit/set 4 time periods

Hold/Timer mode:

- activate and adjust a boost period of up to 24h, by op-

tional setting range temperature

Home/Away mode:

- the thermostat will turn on the heating, if the room tem-

perature drops below the set value.

Holiday mode:

- calendar based and programmable in advance.

OFF mode:

- frost protection included, by adjustable temperature 

range

Battery backup

2 months

Wireless standard, for T60-EW

Wi-Fi 802.11 b/g/n (2.4G)

Appliance and protection class

Class II - IP20

Size, dimensions (H/W/D)

86/96/44 mm

Build-in depth

30 mm

Installation type

Flush, hole pitch 60 mm

Terminals

2.5 mm², screw cage clamp

Terminal wire size

max. 2.5 mm²

Display size

3.5” - Color capacitive touch

Display resolution

480x320 TFT

Optional external floor sensor

NTC (10 kΩ), Class II, 3 meter

Optional external room/air sensor

NTC (10 kΩ), Class II, 3 meter

Max. length sensor cable

50 m, 2 x 1.5 mm²

CE marking

Low Voltage Directive 2014/35/EU

EMC Directive 2014/30/EU

RoHS Directive 2011/65/EU

TE

CHNICAL SPE

CIFICA

TION

23

Summary of Contents for EnergoControl T60-EH

Page 1: ...EnergoControl Touchscreen Thermostat T60 EH and T60 EW User Guide ENGLISH ErP...

Page 2: ...2...

Page 3: ...airing to App Smart Config Temperature Format Temperature Limit Schedule Switch Diff Output Delay Away Mode Defrost Sensor Selection and Calibration Humidity Sensor Calibration Open Window Function Fl...

Page 4: ...LCD Main Display 4...

Page 5: ...ed area If humidity value is between 30 and 60 the pointer will be in the Green area If humidity value is more than 60 the pointer will be in the Grey area Power ON OFF Holiday Displayed when thermost...

Page 6: ...e periods for Saturday and Sunday 7 day programming mode can be programmed each day with 4 time periods 24 hour mode Every day can be edited with 4 time periods Time Clock Mode Allows only the time cl...

Page 7: ...list or manually type in Press Next Enter the WiFi password then press Next On the T60 EW press the icon and enter Feature Settings Find App Matching and press it Wait for the devices to pair This ma...

Page 8: ...02 Hold Mode Timer Function The Temperature Hold function allows you to manually override the current operating program and set a different temperature for a desired period Optimum Start Adaptive Sta...

Page 9: ...ill then auto matically return to the program mode on your return Press the Holiday and enter setting interface For Holiday Start press the column of Year Month Day Use the icons to set the Year Month...

Page 10: ...desired tempera ture For Example The setting temperature is 27 C Day The same as Program Morning procedures For Example The setting time is 10 Hour 40 Minute For Example The setting temperature is 24...

Page 11: ...ection option press it and enter setting interface Select the time zone your desired Press the icon twice to save and return to main display 01 02 03 04 Clock Setting To set the clock follow these ste...

Page 12: ...back light if the ambient light levels drop If you turn the room lights off the back light will dim so the T60 does not light up the room Standby Screen Screen Lock Press the icon and enter Feature S...

Page 13: ...tand by mode Note To unlock the T60 Enter your four digit pin code If you forget your pin code 03 04 Network Setting Applies only for T60 EW Press the icon and enter Feature Settings Find the Network...

Page 14: ...ess the first column use the icons to adjust min temp between 5 44 C Press the second column use the icons to adjust max temp between 6 45 C Press the icon twice to save and return to main display 01...

Page 15: ...output delay can be entered This can be set from 0 15 minutes The default is 0 meaning no delay This function helps to prevent system Short cycling Away A preset temperature while away from the house...

Page 16: ...or Sensor Only external sensor Built in Floor Sensor Remote Air Floor Sensor Note When you enable Remote Air Floor Sensor the floor sensor is used as a floor limiting sensor and is designed to prevent...

Page 17: ...ns the heat off for 15 minutes if it detects that the temperature drops by more than three degrees in less than one minute You can enable or disable the this function in the following way Press the ic...

Page 18: ...on twice to save and return to main display 04 Optimum Start Adaptive Start Work Mode Selection Select if you want the thermostats to work in Heating Mode or Timer Mode The thermostat will restart and...

Page 19: ...gs Find the Reset To Factory Settings option press it and enter the setting interface Press Reset for factory settings The thermostat will automatically restart Warning Reset will make you lose the cu...

Page 20: ...rame of the OFF time and use the icons to adjust to the desired hour Press the Minute frame of the OFF time and use the icons to adjust to the desired minutes Repeat these steps to set all periods 01...

Page 21: ..._______ ____________________________________ ____________________________________ ____________________________________ ____________________________________ ____________________________________ _______...

Page 22: ...22...

Page 23: ...tem perature drops below the set value Holiday mode calendar based and programmable in advance OFF mode frost protection included by adjustable temperature range Battery backup 2 months Wireless stan...

Page 24: ...18 11 07 01EN Energotech AB Firmagatan 5 SE 213 76 Malm Sweden Tel 46 40 866 90 info energotech se www energotech com For latest updated information please visit our website...

Reviews: