Away Mode
The Away Mode is a shortcut button to easily change to a preset temperature when
leaving the premises. The range is 7-35°C, default is 7°C.
In Away Mode, the T60 will only turn the heating ON if/when the room temperature
drop below the set Away Temperature, this is configured in Feature Settings. If
the heating is turned on in Away Mode, the flame symbol will be displayed.
01
02
MODE 1 - THERMOSTAT MODE /
Operation of Main Display
Air Humidity
Shows the indoor air humidity. When tapping on the icon, the display will simulta-
neously show the temperature and humidity. The rate can be calibrated in Feature
Settings, section Humidity Sensor.
01
02
Hold Mode (Timer Function)
The Temperature Hold function allows you to manually override the current operating
program and set a different temperature for a desired period.
Optimum Start / Adaptive Start
The thermostat features an optimum/adaptive function that automatically changes
heating start times, to ensure that the required set point temperature has been reached
during a programmed period.
The thermostat collects data and calculates how much earlier the heating system must
be turned on/off, to achieve the required set point temperature. The fixed rate of change
is 15 minutes, the number of minutes for 1°C temperature rise.
Select/tap “ON” in the OPT Optimum box, if you want the heating to run with
optimum/adaptive function.
Select/tap “OFF” in the OPT Optimum box, if you simply want the heating to start
at the beginning of a set point.