Step 1
Release the display by loosen the screw from the bottom of the
thermostat. Then carefully pull and separate it away from the
base-part, initially from the lower part of the thermostat. Keep
the display in a safe place, to prevent scratches and damage.
Step 2
Attach and secure the base-part to the wall, or over an junction
box, using 2 screws. The hole pitch, center to center, is 60 mm.
Step 3
Connect the wires in accordance with the diagram on page 2.
The wiring diagram must be followed. If the installation wires
are not coming trough the wall, the cable can be entered into
the thermostat by cutting or drilling a hole on one side of the
base-part.
Step 4
When the connection is done, refit the display carefully to the
base-part, starting with the upper part of the thermostat, and
gently tighten the bottom retaining screw.
The thermostats is now ready to operate.
INSTALLATION INSTRUCTION
Thank you for the purchase of our product. Please read the
instruction before mounting and installing.
The device is an electronic thermostat for temperature control
by means of NTC sensors, located either internally within the
thermostat or externally by sensors.
PRODUCT PROGRAM
T60-S
Multi-functional thermostat with built-in sensor and
ability of two external sensors, floor and/or air.
Without Wi-Fi function.
T60-SW
Multi-functional thermostat with built-in sensor and
ability of two external sensors, floor and/or air.
With Wi-Fi function.
ES-T60
Accessory, external floor sensor probe, NTC 10 kΩ.
3 m connection cable.
WARNING – Important Safety Instructions
Disconnect the power supply before carrying out
any installation or maintenance work,on this ther
-
mostat and/or associated components.
The thermostat, and the associated components,
should only be installed by a qualified and autho
-
rized electrician.
Electrical installation must be in accordance with
appropriate national regulations.
MOUNTING OF THE THERMOSTAT
The thermostat is designed to be surface mounted directly onto
the wall or over an recessed
junction box.
PLACEMENT OF THE THERMOSTAT
The thermostat should be placed on the wall, approximately
1.5 m above the floor level, when the built-in sensor is used for
temperature regulation. Ensure and allow free air circulation
around it. Draught and direct sunlight, or other heat sources,
must be avoided. It can affect thermostat functions.
When using a floor sensor, it is strongly recommended to follow
the underfloor heating supplier’s advice and instructions.
The sensor cable, of the accessory ES-T60, may be extended up
to 50 m by means of a separate two-core cable.