Defrost
The thermostat automatically enter the Defrost Mode when the room temperature
drops below the set defrost temperature.
The range is 7-17°C. The default is +7°C and is
suitable for most applications.
system defaults to 0.5°C, meaning that when the temperature is set to 20°C, the
heating will start at 19.5°C and stop at 20°C. If the value is set to 1°C, the heating will
start at 19°C and stop at 20°C.
The switching differential is settable between 0.5°C - 3.0°C .
Output Delay
To prevent rapid switching, an output delay can be entered. This can be set from
0-15 minutes. The default is 0, meaning no delay. This function helps to prevent
system “short cycling”.
Away
There is a preset temperature while you are away from the house. The default is +7°C.
To change/set the temperature, follow these steps:
Press the icon Feature Settings.
Browse to the
“Away” submenu and press
Use the icons to adjust the temperature. The range is 7-35°C
Press the icon twice to save and return to main display
.
01
02
03
04
Press the icon Feature Settings.
Browse to the
“D
efrost
” submenu and press
Temperature Options.
Use the icons to adjust the temperature.
Press the icon twice to save and return to main display
.
01
02
03
04