14
3.5 Fuel Metering Pump and Filter Installation
– EnergyLogic Tank
(continue to section 3.6 if you don’t have EL tank).
On EnergyLogic Tanks, the fuel pump components are mounted on the side as shown. Follow
the steps below to first install the firestop valve and filter head, and then install the pump.
3.5.1 Fire Stop Valve and Filter Head Installation
– EL
Tank.
Decide which end of the tank is the best location for your
pump. On EL 250 gallon and 500 gallon tanks, the pump may
be mounted to either end. To install the firestop valve, first
apply gasket sealer to the ¼” NPT fitting and screw the fire
stop valve to the fuel filter head, fully tighten the NPT threads
using a back up wrench. Then, apply sealer to the ½” NPT
fitting and screw the entire filter head assembly with firestop
valve into the ½” NPT port in the side of the tank (located
about 10” up from the floor).
3.5.2 Metering Pump
Installation
– EL Tank
Mount the pump to the
integrated bracket on the
EnergyLogic tank using (4)
1/4-20 bolts.
Fire-Stop Valve
Filter Head Assembly
Spin On Fuel Filter
Metering Pump
Assembly
Fuel system
– EL Tank
Gasket
sealer here,
then tighten.
FireStop Valve
Filter Head
Assy.
To Tank
(4) 1/4 - 20 Bolts
Remove cover to
install bolts. Replace
cover after pump has
been wired.
Fuel Pump Assembly
Mount Pump to Tank
Call 1-
800-347-9575
for Technical Support