1.2.4 Rapid Mount Commercial
Unistrut
1/8”
WARNING:
Do not put too much tension on the safety cable. There
needs to be a small amount of slack present in the safety cable for
proper functioning. Avoid sharp edges.
Complete safety cable installation and turn to page 50
Tighten both
set screws
After tightening, move the
extension tube back and
forth, then tighten the set
screws again
Level Mount
The safety cable must
be securely attached to
the building structure and
NOT the unistrut
. It can
be attached to I-beams,
steel trusses, or Glulams
as shown in sections 1.2.1,
1.2.2 and 1.2.3. Avoid sharp
edges. If you are unsure
how to secure the safety
cable properly, contact a
structural engineer.
Now Attach safety cable