background image

Figure 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

Testing & Code Compliance

 

UL LISTE  D

 

Motor..............................................................................1/4 HP ,120VAC, 60HZ

Incandescent....................................................................800W-120VAC, 60HZ

Operating Temperature ...................................................32°to 131°F (0°to 55°C)

Adjustable Light Level  ................................................................10FC—150FC
Adjustable Time Delay  ................................................................15 sec.-30min
Sensitivity Adjustment.........................................50% or 100%  (DIP switch 1) 

Coverage……………………...................……………………………Up to 1200 ft

2

Fluorescent ...................................800VA-120VAC / 1600VA-277VAC, 60HZ
Resistive ..........................................................................800W-120VAC, 60HZ

The MPC-50V provides a 360° coverage pattern, up to 1200 square feet. The 

coverage shown represents walking motion at a mounting height of 8 feet(See

 Figure 1 ).For building spaces with lower levels of activity or with obstacles 

and barriers, coverage size may decrease.

44 ft
13.4m

8 ft

22 ft

22 ft

13 ft

13 ft

7 ft

7 ft

3 ft 0

3 ft

Typical

desk-top

level

Coverage Pattern

Description:

 

The MPC-50V 360 °passive infrared (PIR) occupancy sensors turn lighting systems 

on and off based on occupancy and ambient light levels.  The light level feature keeps lights from 

turning on if the ambient light level is sufficient.  The sensors can be configured to turn lighting on, 

and hold it on as long as the sensor detects occupancy.  After no movement is detected for a 

specified time  the lights are switched off. 

                                           

360° 

Passive Infrared

 

L

ine

 Voltage Occupancy Sensor

 

Model #: M

P

C-50

V

G

eneral

 

Specification 

Passive Infrared 
Technology(PIR) 

360 °  field of view,

1200sqft

 

Time Delay is adjustable 
from 5

 

seconds to 30 

minutes

Simple, fast installation

Adjustable sensitivity 
settings

Light level is adjustable. 

 

Specifications

 

Features

Summary of Contents for MPC-50V

Page 1: ...13 4m 8 ft 22 ft 22 ft 13 ft 13 ft 7 ft 7 ft 3 ft 0 3 ft Typical desk top level Coverage Pattern Description The MPC 50V 360 passive infrared PIR occupancy sensors turn lighting systems on and off based on occupancy and ambient light levels The light level feature keeps lights from turning on if the ambient light level is sufficient The sensors can be configured to turn lighting on and hold it on ...

Page 2: ...witch to thesensor by connecting the Grey wires Step 4 is not necessary if you don t want to use the function of MANUAL ON OFF Figure 2 mounting Mounting Using an Octagonal Junction Box 1 Pull the high voltage wires into the J Box through the conduit knockout 2 Connect the high voltage wires to the appropriate terminals on the sensor 3 Loosen the appliance mounting screws attached to the J Box 4 A...

Page 3: ... MAX DIP switch 1 OFF 3 Ensure that the Light Level is at the maximum position see LIGHT LEVEL seconds If not see TROUBLESHOOTING 5 Move about the coverage area The lights should come on When testing and adjustment is complete reset DIP Switches Time Delay and Light Level to the desired settings and replace the cover on the sensor ADJUSTMENT Sensor Test Refer to the Figure 8 above Note There is a ...

Page 4: ...s occupancy is detected The sensor time delay operates as programmed When the load turns OFF due to lack of occupancy detection the load can be turned ON again by occupancy detection or switch activation b Turn the lights OFF manually when it is ON 1 When the load is turned OFF manually as long as the sensor continues to detect occupancy the load stays OFF Selected time after the last occupancy de...

Reviews: