2. When the load is turned OFF manually, pressing the switch again turns the load

2. 100% ,  the maximum range of sensor's coverage is 1200 square feet( see

“COVERAGE PATTERN”)

Manual on function is achieved by using a momentary switch, such as the YQDS-

115-M momentary switch. The switch connected to the two grey wires(22AWG). Each

press the switch, the load will be reverted. The operation of the sensor connected

to manual switch depends on the DIP switch 2 setting.

Turn the lights on manually .When motion is no longer detected in a 

selected time ,lights will change to OFF.When the selected time expires, the sensor 

will change to ON automatically if motion is detected again in 30 seconds.

  In this mode ,when motion is detected in the area ,lights turn  on  

automatically; When motion is no longer detected, light remain ON for a selected

 time, when the selected time expires ,lights turn off automatically.

a. The load can be turned ON by manual switch activation and it stays on as long

as occupancy is detected. The sensor time delay operates as programmed. When

the load turns OFF due to lack of occupancy detection, the load can be turned ON

again by occupancy detection or switch activation.

b.Turn the lights OFF manually when it is ON.

1. When the load is turned OFF manually, as long as the sensor continues to detect

occupancy the load stays OFF. Selected time after the last occupancy detection,

the lights stay off and the sensor reverts to the automatic-on mode.

ON and the sensor reverts to the automatic-on mode.

3. Once the sensor returns to automatic-on mode, either the switch or occupancy

detection can turn the load ON

Vacancy Mode: DIP Switch 2

Enabled State : 

Disabled State : 

A manual switch provides the following additional functionality:

Enerlites Inc.  

www.enerlites.com

  

Phone: 949-756-0536  Fax: 949-756-0528   e-mail: 

sales@enerlites.com

 

Date: 

03

/

01

/201

6

 

1. 50% , sensor’s coverage is smaller, just about half of the widest range.

DIP Switch Setting

The MPC-50V has 2 DIP switches under the cover. They are used to set sensitivity,

 vacancy mode feature settings.

=OFF     =ON      

Sensitivity setting: DIP Switch 1

Sensitivity

50%

100%

Vacancy

Enabled

Disabled

1

2

=Factory Setting

Summary of Contents for MPC-50V

Page 1: ...13 4m 8 ft 22 ft 22 ft 13 ft 13 ft 7 ft 7 ft 3 ft 0 3 ft Typical desk top level Coverage Pattern Description The MPC 50V 360 passive infrared PIR occupancy sensors turn lighting systems on and off based on occupancy and ambient light levels The light level feature keeps lights from turning on if the ambient light level is sufficient The sensors can be configured to turn lighting on and hold it on ...

Page 2: ...witch to thesensor by connecting the Grey wires Step 4 is not necessary if you don t want to use the function of MANUAL ON OFF Figure 2 mounting Mounting Using an Octagonal Junction Box 1 Pull the high voltage wires into the J Box through the conduit knockout 2 Connect the high voltage wires to the appropriate terminals on the sensor 3 Loosen the appliance mounting screws attached to the J Box 4 A...

Page 3: ... MAX DIP switch 1 OFF 3 Ensure that the Light Level is at the maximum position see LIGHT LEVEL seconds If not see TROUBLESHOOTING 5 Move about the coverage area The lights should come on When testing and adjustment is complete reset DIP Switches Time Delay and Light Level to the desired settings and replace the cover on the sensor ADJUSTMENT Sensor Test Refer to the Figure 8 above Note There is a ...

Page 4: ...s occupancy is detected The sensor time delay operates as programmed When the load turns OFF due to lack of occupancy detection the load can be turned ON again by occupancy detection or switch activation b Turn the lights OFF manually when it is ON 1 When the load is turned OFF manually as long as the sensor continues to detect occupancy the load stays OFF Selected time after the last occupancy de...

Reviews: