background image

Australia and New Zealand

Actuant Australia Ltd. 
Block V Unit 3
Regents Park Estate
391 Park Road
Regents Park NSW 2143
(P.O. Box 261) Australia
T +61 

(0)2 

9743 

8988

F +61 

(0)2 

9743 

8648

sales-au@enerpac.com

Brazil 

Power Packer do Brasil Ltda.
Rua dos Inocentes, 587
04764-050 - Sao Paulo (SP)
T  +55 11 5687 2211
F  +55 11 5686 5583
Toll Free: 0800 891 5770
vendasbrasil@enerpac.com

Canada

Actuant Canada Corporation
6615 Ordan Drive, Unit 14-15
Mississauga, Ontario L5T 1X2
T  +1 905 564 5749
F  +1 905 564 0305
Toll Free:
T   +1 800 268 4987
F  +1 800 461 2456
customer.service@actuant.com

China

Actuant (China) Industries Co. Ltd.
No. 6 Nanjing East Road,
Taicang Economic Dep Zone
Jiangsu, China
T  +86 0512 5328 7500 
F  +86 0512 5335 9690
Toll Free: +86 400 885 0369
sales-cn@enerpac.com

France, Switzerland, North Africa 
and French speaking African 
countries

ENERPAC 
Une division d’ACTUANT France S.A.
ZA de Courtaboeuf
32, avenue de la Baltique 
91140 VILLEBON /YVETTE
France
T  +33 1 60 13 68 68
F  +33 1 69 20 37 50
sales-fr@enerpac.com

Germany and Austria

ENERPAC GmbH
P.O. Box 300113
D-40401 Düsseldorf
Willstätterstrasse 13
D-40549 Düsseldorf, Germany
T  +49 211 471 490
F  +49 211 471 49 28
sales-de@enerpac.com

India

ENERPAC Hydraulics Pvt. Ltd.
No. 1A, Peenya Industrial Area
IInd Phase, Bangalore, 560 058, India
T  +91 80 40 792 777
F  +91 80 40 792 792
sales-in@enerpac.com

Italy

ENERPAC S.p.A.
Via Canova 4
20094 Corsico (Milano)
T +39 

02 

4861 

111

F +39 

02 

4860 

1288

sales-it@enerpac.com

Japan

Applied Power Japan LTD KK
Besshocho 85-7
Kita-ku, Saitama-shi 331-0821, Japan
T +81 

48 

662 

4911

F +81 

48 

662 

4955

sales-jp@enerpac.com

Middle East, Egypt and Libya

ENERPAC Middle East FZE
Office 423, LOB 15
P.O. Box 18004, Jebel Ali, Dubai
United Arab Emirates
T +971 

(0)4 

8872686

F +971 

(0)4 

8872687

sales-ua@enerpac.com

Russia

Rep. office Enerpac
Russian Federation
Admirala Makarova Street 8
125212 Moscow, Russia
T +7 

495 

98090 

91

F  +7 495 98090 92
sales-ru@enerpac.com

Singapore

Actuant Asia Pte Ltd.
83 Joo Koon Circle 
Singapore 629109
T +65 

68 

63 

0611

F +65 

64 

84 

5669

Toll Free: +1800 363 7722
sales-sg@enerpac.com

South Korea

Actuant Korea Ltd.
3Ba 717, Shihwa Industrial Complex
Jungwang-Dong, Shihung-Shi, 
Kyunggi-Do
Republic of Korea 429-450
T +82 

31 

434 

4506

F +82 

31 

434 

4507

sales-kr@enerpac.com

Spain and Portugal

ENERPAC SPAIN, S.L. 
Avda. Los Frailes, 40 – Nave C & D
Pol. Ind. Los Frailes
28814 Daganzo de Arriba
(Madrid) Spain
T +34 

91 

884 

86 

06

F +34 

91 

884 

86 

11

sales-es@enerpac.com

Sweden, Denmark, Norway, Finland 
and Iceland

Enerpac Scandinavia AB
Fabriksgatan 7
412 50 Gothenburg
Sweden
T  +46 (0) 31 799 0281
F  +46 (0) 31 799 0010
scandinavianinquiries@enerpac.com

The Netherlands, Belgium, 
Luxembourg,
Central and Eastern Europe, 
Baltic States, Greece, Turkey 
and CIS countries

ENERPAC B.V.
Galvanistraat 115
6716 AE Ede 
P.O. Box 8097
6710 AB Ede
The Netherlands
T +31 

318 

535 

911 

F +31 

318 

535 

848

sales-nl@enerpac.com

Enerpac Integrated Solutions B.V.

Opaalstraat 44
7554 TS Hengelo
P.O. Box 421
7550 AK  Hengelo
The Netherlands
T  +31 74 242 20 45
F  +31 74 243 03 38
integratedsolutions@enerpac.com

South Africa and other English 
speaking African countries

Enerpac Africa Pty Ltd.
No. 5 Bauhinia Avenue
Cambridge Office Park
Block E
Highveld Techno Park
Centurion 0157
South Africa 
T: +27 12 940 0656

United Kingdom and Ireland

ENERPAC Ltd., 
Bentley Road South
Darlaston, West Midlands
WS10 8LQ
England
T  +44 (0)121 50 50 787
F  +44 (0)121 50 50 799
sales-uk@enerpac.com

USA, Latin America and Caribbean

ENERPAC 
P.O. Box 3241
 Milwaukee WI 53201 USA
T  +1 262 293 1600
F  +1 262 293 7036
User inquiries:
T  +1 800 433 2766
Distributor inquiries/orders:
T  +1 800 558 0530
F +1 

800 

628 

0490

Technical inquiries:
 techservices@enerpac.com
sales-us@enerpac.com

Enerpac Worldwide Locations 

e-mail:

 info@enerpac.com

 

internet:

 www.enerpac.com

All Enerpac products are guaranteed 
against defects in workmanship and 
materials for as long as you own them.

For the location of your nearest authorized 
Enerpac Service Center, visit us at
www.enerpac.com

101711

Summary of Contents for Pow'r-Riser PR Series

Page 1: ...a margin of safety that accounts for possible shifting loads or side loading conditions DANGER To avoid serious personal injury keep hands and feet away from hydraulic cylinder and related components...

Page 2: ...PRAMA100__L PRASA100__L 9 700 669 PRASA150__L 10 200 703 PRASA200__L 10 200 703 Load Rating Model US Tons Metric Tons kN PRAMA060__L 60 54 533 PRAMA100__L PRASA100__L 100 90 889 PRASA150__L 150 136 1...

Page 3: ...s the motor will start automatically when either pendant button is depressed 3 Open the air supply valve callout 4 Using the regulator knob adjust the air pressure to a minimum of 80 psi 5 5 bar IMPOR...

Page 4: ...y support the load for any period of time after the lift has been completed Support the load with U Rings or other suitable load supports immediately after it has been lifted to the desired height WAR...

Page 5: ...valve to stop the motor AFTER COMPLETING THE JOB Fully retract the cylinder and close the air supply valve With the motor off shift the control valve several times between the extend and retract posi...

Page 6: ...compensated for by use of plywood or other suitable compression material alone Table 6 Load Caps Jack Model Load Cap Model Numbers Non Swivel Load Cap standard Swivel Load Cap optional accessory PRAM...

Page 7: ...Cap Steel U Ring top Recess of U Ring Steel U Ring bottom Aluminum U Rings Locator on each U Ring and at top of cylinder housing Figure 5 U Ring Stacking Arrangement typical 6 0 MAINTENANCE 6 1 Maint...

Page 8: ...gulator Figure 6 Oil Change 6 3 Air Line Filter Regulator See Figure 7 Every 30 hours of operation Check the lter bowl for water Drain any water if present Inspect air lter element inside lter bowl Re...

Page 9: ...nsufficient compressed air volume Check air regulator setting Increase volume of compressed air or increase size of supply air line to meet air ow and pressure requirements Internal pressure leaks or...

Page 10: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Page 11: ...gato Permitir un margen de seguridad que prevenga la posibilidad de desplazamiento o desviaci n de la carga PELIGRO Para evitar lesiones personales mantenga las manos y los pies alejados del cilindro...

Page 12: ...l nivel del lubricador para l nea de aire anotaci n 7 y a ada m s lubricante si es necesario Utilice un aceite detergente SAE 10 ISO 32 o un lubricante anticongelante autorizado Consulte la Secci n 6...

Page 13: ...edas 19 V lvula de aire del neum tico 20 Almacenamiento de los anillos en U No disponible en todos los modelos RAISE LOWER 7 1 15 3 18 19 16 13 5 8 9 7 12 4 10 11 2 14 20 Figura 1 Caracter sticas y co...

Page 14: ...a corta PRASA20016L est equipado con dos c ncamos para izar Los modelos de carrera corta de la serie PRAMA060 PRA_A100 y PRASA150 no tienen instalados c ncamos para izar ADVERTENCIA Eleve el gato util...

Page 15: ...ula de control a la posici n central neutral de retenci n Si el gato tiene un mando remoto libere el bot n de la echa hacia arriba para que la v lvula vuelva a la posici n central neutral de retenci n...

Page 16: ...pcionales Modelo de piezas de distancia Anchura de cada uno mm Pulgadas PRS1 25 1 PRS2 51 2 PRS3 76 3 Conjunto de piezas de distancia PRS4 El conjunto incluye PRS1 PRS2 y PRS3 1 cada uno PRECAUCI N Nu...

Page 17: ...cilindro extendido Est n disponibles en 5 longitudes diferentes para cada modelo de Pow r Riser Assembled View Anillo de soporte de carga Plataforma de carga Anillo en U de acero parte superior Anillo...

Page 18: ...alcance los 60 C 150 F Cuando haya un alto grado de humedad en el entorno y o cambios de temperatura extremos que puedan provocar la condensaci n del aceite dentro del dep sito Cuando haya un entorno...

Page 19: ...lenciador v ase la gura 8 Cada 30 horas de funcionamiento Compruebe que no haya suciedad en el silenciador Si est obstruido reemplace el silenciador por uno nuevo que tenga las mismas especi caciones...

Page 20: ...r ulico en un centro de servicio t cnico autorizado Enerpac Repare o sustituya los componentes seg n sea necesario Ajuste demasiado bajo de la v lvula de descarga interna o de la v lvula de alivio en...

Page 21: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Page 22: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Page 23: ...____________________________________________________________ _______________________________________________________________________________________ ___________________________________________________...

Page 24: ...7 495 98090 92 sales ru enerpac com Singapore Actuant Asia Pte Ltd 83 Joo Koon Circle Singapore 629109 T 65 68 63 0611 F 65 64 84 5669 Toll Free 1800 363 7722 sales sg enerpac com South Korea Actuant...

Reviews: