Never set the relief valve to a higher pressure than the maximum 
rated pressure of the pump. Higher settings may result in equipment 
damage or personal injury. Do not remove relief valve.    

To avoid personal injury keep hands and feet away from cylinder and 
work piece during operation. 

Do not handle pressurized hoses. 
Escaping oil under pressure can penetrate the skin, causing serious 
injury. If oil is injected under the skin, see a doctor immediately.

Do not pressurize disconnected couplers.

Safety First

Read all instructions, DANGER, WARNING and 
CAUTION paragraphs carefully.  
Follow all safety precautions to avoid personal 
injury or property damage during system 
operation. Save these instructions.

ENERPAC cannot be responsible for damage or 
injury resulting from unsafe product use, lack of 
maintenance or incorrect product and/or system 
operation.  Contact ENERPAC when in doubt as 
to the safety precautions and operations

Conformance to        

National & International 

Standards.

We declare that this product has been tested 
and conforms to applicable standards and is 
approved to carry the CE, TUV C and US, and 
FCC certification marks. An EC Declaration of 
Conformity is enclosed separately.

Model / Serial Number

The model and serial number are found on the 
back side of unit, above the battery area.

Important

Danger icons are only used when your action or lack 

of action may cause serious injury or even death.

Failure to comply with DANGER, WARNING or CAUTION statements 
could cause equipment damage and personal injury.

General Safety   

4

Electrical Safety  

6

Installation  

7

Use  

 

8

Operation 9
Disconnecting 10
Oil Fill   

11

Pressure Setting 

12

Technical Specifications  

13

Troubleshooting 14

Contents

Summary of Contents for XC-Series

Page 1: ...XC Series Cordless Hydraulic Pump Instruction Manual 3...

Page 2: ...age or injury resulting from unsafe product use lack of maintenance or incorrect product and or system operation Contact ENERPAC when in doubt as to the safety precautions and operations Conformance t...

Page 3: ...jack or cylinder to a pump with a higher pressure rating Wear proper personal protective gear when operating hydraulic equipment Be sure setup is stable before lifting load Cylinders should be placed...

Page 4: ...attery pack Recharge only with the charger specified by the manufacturer A charger that is suitable for one type of battery pack may create risk of fire when used with another battery pack Use the ENE...

Page 5: ...7 Installation 1 4 5 6 60 70 Nm 44 53 ft lb 2 11 16 15 16 3 8 NPTF 60 Min 100 3 Gauge Recommended...

Page 6: ...8 Use 1 2 3 Optional Strap Shown...

Page 7: ...9 Operation 2 1 3 4 5 P 6...

Page 8: ...10 Disconnecting 2 4 3 P 1...

Page 9: ...11 Oil Fill 2 3 4 5 6 1 4 1 4 4 5 5 7 Nm 40 50 in lb 13mm Pour slowly P 1...

Page 10: ...12 Pressure Setting Factory Setting User Adjustable 2 1 7 32 x 6 PMAX 700 bar 10 000 psi 70 MPa 3 PMAX 700 bar 10 000 psi 70 MPa Pmin 150 bar 2 175 psi 15 MPa Flat head screwdriver...

Page 11: ...2 0 120 10 8 23 8 XC 1202M Maximum Pressure Flow Rate Fig A Valve Function Motor Battery No load 2 000 psi 140 bar Max Load Voltage Type 700 bar 2 05 l min 0 50 l min 0 25 l min Advance Release 0 37...

Page 12: ...l damage to pump Contact ENERPAC service center Cylinder will not advance or retract Oil level low Add oil until reservoir is completely full Oil intake screen clogged Contact ENERPAC service center V...

Page 13: ......

Page 14: ...rates T 971 0 4 8872686 F 971 0 4 8872687 sales ua enerpac com Russia Rep office ENERPAC Russian Federation Admirala Makarova Street 8 125212 Moscow Russia T 7 495 98090 91 F 7 495 98090 92 sales ru e...

Reviews: