1.0      SAFETY FIRST  !!!

 

 
Read all instructions, warnings and cautions 
carefully. Follow all safety precautions to avoid  
personal injury or property damage during 
system operation. Enerpac cannot be 
responsible for damage or injury resulting from 
unsafe product use, lack of maintenance or 
incorrect product and/or system operation. 
Contact Enerpac when in doubt as to the safety 
precautions and operations.      
 

IMPORTANT: Before using the product 

it’s important for the operator to read the 
instructions and to understand the precautions, 
the warnings, and to apply the local codes of 
security.

 

  
2.0

 

DESCRIPTION OF THE PRODUCT :

 

The “ENERPAC”  air driven hydraulic pumps 

 

model  YPA3174D  , are manual pumps realised for 
single acting tensioners, the components are 
described in fig. 1 and 2, while the characteristics of 
the pump M189D are indicated in the graph page 7.

 

In fig.2 we find the air input for alimentation of the 
pump (pos.25),  made of a fitting with ½ BSP thread 
to be equipped with an air fitting, not include, 
compatible with the equipment where the pump will 
be used. The oil output(pos. 11) is a female rapid 
coupler

 

.

 

3.0    INSTALLATION 

 

 

3.1   GENERAL: The Enerpac pumps are supplied 
ready to use, complete with hydraulic oil.  The 
safety valve is preset as the relief valves.  

 

These values can be changed only by qualified 
personal.  

 

3.2   PRELIMINARY OPERATIONS:

 

1

 

Position the pump near the work area, assure 
that the hoses and the pendant can reach easily 
the wrench.

 

2

 

Check that the alimentation of the 
compressed air is able to give a 
minimum of 300 Nl/min at 6.5 bar  

 

 
3

 

Check the pressure setting as described at point 
3.3

 

4      Check that the couplers are well connected..

 

 ATTENTION: Always mount the protection 

caps on the couplers when not used. Do not 
pressurise flexible hoses without connecting the 
couplers.

 

 
 
 

3.3  REGULATION PRESSURE:

 

       Verify what is the working pressure needed for 
the  tensioning

 

 

Connect the alimentation hose to the fitting for 
air alimentation pos. 25

 

 

Connect the flexible oil hose at the output of the 
pump (pos. 11) leaving the other hose end with 
the coupler free(the hose must be able to be 
pressurized)

 

 

 ATTENTION: avoid that the hose free end, 

during the pressure regulation is pointing towards 
persons or animals; an eventual break of the coupler 
could eject metal parts which could be harmful.

 

 

Lift and turn counterclockwise the air tap on the air 
regulator(pos.3) until it  is completely open

 

 

Shut the the relief valve(pos. 15) turning clockwise.

 

 

Open the air valve(pos. 42).

 

 

Turn clockwise the air tap (pos.3) slowly until you 
reach the working pressure of the oil(see the 
performance graph pag.7) shown on the gauge of 
the front panel(pos. 6), while trough the air valve it 
is possible to the air pressure

 

 

When the working pressure is reached  close  the air 
valve(pos. 42)

 

 

 

Lock the air tap, lowering it(pos.3) and open the 
relief valve(pos. 15) turning counterclockwise to set 
the pressure of the circuit to zero

 