background image

171 505 44  07-01

   

Gph

8

9

10

11

kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h kg/h 

kW 

Mcal/h

0,40

1,33

16

13

1,41

17

14

1,49

18

15

1,56

18

16

0,50

1,66

20

17

1,76

21

18

1,86

22

19

1,95

23

20

0,60

2,00

24

20

2,12

25

22

2,23

26

23

2,34

28

24

0,65

2,16

26

22

2,29

27

23

2,42

29

25

2,54

30

26

0,75

2,49

29

25

2,65

31

27

2,79

33

28

2,93

35

30

0,85

2,83

33

29

3,00

36

31

3,16

37

32

3,32

39

34

1,00

3,33

39

34

3,53

42

36

3,72

44

38

3,90

46

40

1,10

3,66

43

37

3,88

46

39

4,09

48

42

4,29

51

44

1,20

3,99

47

41

4,24

50

43

4,47

53

46

4,68

55

48

1,25

4,16

49

42

4,40

52

45

4,65

55

47

4,88

58

50

1,35

4,49

53

46

4,76

56

48

5,02

59

51

5,27

62

54

1,50

4,98

59

51

5,29

63

54

5,58

66

57

5,85

69

60

1,65

5,49

65

56

5,82

69

59

6,14

73

63

6,44

76

66

1,75

5,82

69

59

6,18

73

63

6,51

77

66

6,83

81

70

2,00

6,65

79

68

7,06

84

72

7,45

88

76

7,81

93

80

2,25

7,49

89

76

7,94

94

81

8,38

99

85

8,78

104

89

2,50

8,32

99

85

8,82

105

90

9,31

110

95

9,76

116

99

2,75

9,15

108

93

9,71

115

99

10,24

121

104

10,73

127

109

3,00

9,98

118

102

10,59

126

108

11,16

132

114

11,71

139

119

3,50

11,65

138

119

12,35

146

126

13,03

154

133

13,66

162

139

4,00

13,31

158

136

14,12

167

144

14,89

176

152

15,62

185

159

4,50

14,97

177

153

15,88

188

162

16,75

198

171

17,57

208

179

5,00

16,64

197

170

17,65

209

180

18,62

221

190

19,52

231

199

5,50

18,30

217

187

19,42

230

198

20,48

243

209

21,47

255

219

6,00

19,97

237

204

21,18

251

216

22,34

265

228

23,42

278

239

6,50

21,63

256

220

22,94

272

234

24,20

287

247

25,37

301

259

7,00

23,29

276

237

24,71

293

252

26,06

309

266

27,33

324

279

7,50

24,96

296

254

26,47

314

270

27,92

331

285

29,28

347

298

8,00

26,62

316

271

28,24

335

288

29,79

353

304

31,23

370

318

8,50

28,28

335

288

30,00

356

306

31,65

375

323

33,18

393

338

9,00

29,95

355

305

31,77

377

324

33,59

398

342

35,14

417

358

NOZZLE TABLE

Pump pressure bar

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

Burner with preheater

Consider that on preheating the oil quantity is reduced by 5-20% depending on.
-  Rise in temperature at the nozzle
-  Design of nozzle
-  Capacity (high capacity - small difference)

1(2)

Summary of Contents for Bentone B40 CN

Page 1: ...Providing sustainable energy solutions worldwide 178 032 53 2 2016 07 08 Installation and maintenance instruction B40 CN...

Page 2: ......

Page 3: ...y 5 Ignition cable 6 Ignition transformer 7 Photo cell 8 Control box 9 Reset button 10 Cover inspection glass 11 Fan wheel 12 Motor 13 Nozzle assembly adjustment 14 Blast tube 15 Air adjustment 16 Air...

Page 4: ...deinite spray angle or spray pattern Recommended nozzle Output range and nozzles recommended The net caloriic value of 11 86 kWh kg for light oil has been used Burner tube Length of burner tube Measu...

Page 5: ...s fol lows Increase the nozzle assembly adjustment somewhat The CO2 con tent and consequently the air volume will then be reduced GENERAL INSTRUCTIONS Condensation in chimney A modern burner works wit...

Page 6: ...ch off power at the main switch and cut off the oil supply Open the cover and disconnect the connecting pipes by loosening screw A Service of burner head 1 Loosenorswingouttheburner from the boiler 2...

Page 7: ...l burner control A2 Twin thermostat F1 Fuse max 10A H1 Alarm lamp H2 Signal lamp optional M1 Burner motor P1 Time meter optional R1 Photoresistor S3 Main switch T1 Ignition transformer Y1 Solenoid val...

Page 8: ...e burner will make an attempt to re start 3 4 Operating position If the burner operation is interrupted by means of the main switch or the thermostat a new start takes place when the conditions in acc...

Page 9: ...blesapplytoastandardfueloilof normal commercial quality according tocurrentstandards Oncommissioning with an empty tube system the oil pump should not be run without oil for more than 5 min a conditio...

Page 10: ...f the pump is overloaded i e If you try to get out more oil than the gear setcansupplyunderexistingcircum stances the oilpressurefallsbelowthe setvalue andthevalveclosesagainst 171 505 10 10 01 Replac...

Page 11: ...93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14...

Page 12: ...1 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 9...

Page 13: ...f magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photocel...

Page 14: ......

Page 15: ...the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...

Reviews: