8
15
Temperature difference of solar water pump
start
2~20
10
℃
Adjustable
16
Disinfection days set
7~28
7
Adjustable
17
Expansion valve min.steps(Ambient
temperature≥5
℃
)
8
~
15
10*10P
Adjustable
18
Expansion valve min.steps(Ambient
temperature<5
℃
)
8
~
10
8*10P
Adjustable
19
Defrosting expansion valve set
2
~
45
40*10P
Adjustable
20
Expansion valve allowed exhaust
temperature
70
~
120
100
℃
Adjustable
21
Ambient temperature when allow defrosting
0
~
50
15
℃
Adjustable
22
Temperature difference between ambient
and coil when start defrosting
1
~
20
2
℃
Adjustable
23
Exhaust high temperature protection value
50
~
110
105
℃
Adjustable
24
Compressor running time when start electric
heater
1
~
24hours
10hours
Adjustable
IV. Technical Parameters
1. Dimension
A
B
BC-F20HWR2-200L
570
1871
Summary of Contents for BC-F20HWR2-200L
Page 2: ......
Page 29: ...26 l Mode settings Click on the main interface to switch modes select what you need ...
Page 32: ...29 ...
Page 33: ...30 ...