6.3 The wire leads of wind turbine and connection wires of battery should refer to wire 
requirement and regulations:

6.4 Please read carefully about controller instructions to set the functions after the completion 
of system wiring, such as model selection and regular time setting:

6.5 PV charging debug: in the light condition (output voltage of solar panel is greater than that 
of battery), the controller's PV indicator should be working (normal on or linking), measure 
output current by DC clamp meter, the current size depends on illumination intensity and 
battery capacity;

6.6 Wind turbine charging debug: wind turbine operation is normal or not when it is windy, 
while reach or exceed cut-in wind speed, the controllers wind turbine indicator should be 
working (normal on or blinking), measure output current by AC clamp meter, the current size 
depends on wind speed and battery capacity:

6.7 Light-control function debug: measure battery voltage by multimetre to ensure battery 
voltage is higher than over discharge recovery voltage, then set to light-control mode, discon-
nect any wire of solar panel from controler, several minutes later, observe whether the light of 
loads is on or not, it is normal it the light is on. Then connect the solar panel wire with control-
ler again. the load output is cut off a few minutes later and the light goes out:

6.8 Time-control function debug: ensure battery voltage is higher than over discharge recov-
ery voltage, observe whether the lighting time of load output light is the same as that of 
setting.

7 Maintenance

Although your high reliabity of wind turbine baa been designed to run for long periods with-
out requiring any maintenance, reliability and performance will be enhanced if you periodical-
ly inspect your system.

The following situations need regular maintenance:

Maintenance item

Check the rope tightness of tower

Check the working condition of the whole

system and connector tightness

Maintain battery (refer to battery manual)

Check all electrical connections to make sure

they are tight and free from corrosion

Wash off any built-up dirt or debris from the

blades and check blades for chip or nicks

Check damaged degree of nosecone

Replace blades

Replace battery

After

storm

Every

six

months

Every

year

Every

two

years

Every

five

years

Summary of Contents for GE-600-24

Page 1: ...GE 600 24 USER MANUAL...

Page 2: ...Do not place the controller inverter and battery in damp rain vibration corrosion and strong electromag netic interference environment the places in direct sunlight near heater or the other heat sour...

Page 3: ...far as possible 2 2 If install two wind turbines on one area the distance between them is 8 10 times of rotor diameter Try to locate the wind turbine in the cleanest turbulent free air as possible Tu...

Page 4: ...m Power supply system for ship home or farm 4 Wind Turbine Assembly GE wind turbine assembly has been nished in the factory installation on site is simpler mainly including mounting blades on the hub...

Page 5: ...ton 2 Mounting the hub with blades onto the motor shaft 3 Tightening the hub by nuts and spring washer and locking up split pin 4 Pressing the cone onto hub strength equally 4 2 Flanged joint assembly...

Page 6: ...controller which is mainly used in low wind speed areas 5 2 Inverter For customers who need AC power it is recommended to use AC220V 50HZ or AC110V 130HZ Inverter the capacity should be determined acc...

Page 7: ...of 5 or less for sites with a 5 4m s average wind speed assuming the standard Rayleigh distribution of wind speeds which is su cient for most sites Refer to the appropriate chart for your system volt...

Page 8: ...to light control mode discon nect any wire of solar panel from controler several minutes later observe whether the light of loads is on or not it is normal it the light is on Then connect the solar p...

Page 9: ...the turbine alternator shaft is damaged the tower is out at vertical in case of these situations the shaft should be replaced and tower verticality must be adjusted 8 5 Generator Abnormal ac Output G...

Page 10: ...ontroller is burned out and needs to be replaced 4 The mode setting on the controller is not correct and needs to be reset according to controller manual 8 9 Wind turbine does not charge battery This...

Page 11: ...voltage up to the recovery of the set points the lights go out Controller detected battery voltage over set limits lights ash voltage down to the recovery of the set points the lights go out Over volt...

Page 12: ...Connected the outside wind generator solar panels street lamp and batteries Safety plate burned open circuit then indicates keep bright state In the case charger over current load over current etc it...

Page 13: ...ator W phase input 6 2 The second loaded negative output 7 2 The second loaded positive output 8 1 The rst loaded negative output 9 1 The rst loaded positive output 10 Battery Batteries positive input...

Reviews:

Related manuals for GE-600-24