Commissioning the system with settings
wizard
The check list covers the whole settings wizard.
Make sure that the installation of ventilation is done
before starting the settings wizard. If the external sensor
connection is removed or if the indoor temperature is less
than +15°C, the settings wizard cannot be run. Alarms
cannot be checked in the settings wizard. If there is an
alarm during the settings wizard, it can be acknowledged
only after the settings wizard is done.
If you pause the setting configuration, the control panel
will automatically restart the wizard when you switch the
ventilation system on the next time. Then you can finalize
the settings.
If the eAir panel is showing a text about connecting to a
network and it is not connecting to the wall mount, check
first the connection between the wall mount and the
ventilation unit.
Do no
tap the
Re-connect radio
button.
It removes the pairing between the wall mount and eAir
panel, after which the eAir panel cannot be used before a
new pairing is formed as instructed on page 162.
Make sure before starting the settings function that all the
necessary information is available. Request the necessary
Modbus parameters from the supplier of the control
system linked with Modbus, and network settings from
the administrator of local area network (only if DHCP is not
in use).
1. Switch the ventilation unit on.
2. The panels starts automatically and the Enervent
logo appears on the screen.
3. Wait for the language choice to appear.
4. This may take some time. Wait patiently.
5. Choose the correct language and tap
Next
.
6. Settings wizard opens.
7. Begin defining settings by tapping
Next
.
The following pages contain all the settings in the
settings wizard.
The blower settings for different modes must be
configured and set on a house-by-house basis.
FOR INFORMATION
Summary of Contents for LTR-3 eAir
Page 8: ...8 Kanavaliitännät ulkoilma tuloilma poistoilma jäteilma ...
Page 20: ...20 11 13 9 12 Lisävaruste 1 2 min 10 ...
Page 48: ...48 ...
Page 51: ...51 Ammattilaisen asennusohje ...
Page 52: ...52 LTR 3 eAir Installationsanvisningar för ventilationsaggregat Svenska ...
Page 58: ...58 Kanalanslutningar uteluft tilluft frånluft avluft ...
Page 70: ...70 9 13 15 11 10 14 Extra tillbehör 1 2 min 12 ...
Page 98: ...98 ...
Page 101: ...101 Installationsanvisningar för yrkesfolk ...
Page 102: ...102 Installeringsinstruksjoner for ventilasjonsenheten Norsk LTR 3 eAir ...
Page 108: ...108 Kanalkoblinger utendørsluft tilluft avtrekksluft avkastluft ...
Page 120: ...120 9 13 15 11 10 14 1 2 min 12 ...
Page 148: ...148 ...
Page 151: ...151 Installasjonsinstrukser for fagfolk ...
Page 152: ...152 LTR 3 eAir Installation instructions for the ventilation unit English ...
Page 158: ...158 Duct connections outdoor air supply air extract air exhaust air ...
Page 170: ...170 9 13 15 11 10 14 Extra 1 2 min 12 ...
Page 198: ...198 ...
Page 203: ...203 Koblinger Connections ...
Page 204: ...204 ...
Page 205: ...205 ...
Page 206: ...206 ...
Page 207: ...207 ...
Page 208: ...208 ...
Page 209: ...209 ...
Page 210: ...210 ...
Page 211: ...211 ...
Page 212: ...212 ...
Page 214: ...214 eAir W Periaatekaavio eAir W Principschema eAir W Prinsippskisse eAir W Principle schema ...
Page 215: ...215 ...
Page 218: ...218 ...
Page 219: ...219 ...