80
Eco mode
When you select Eco mode in the ventilation system, the
system will save energy by making minor adjustments to
the set temperature and airflow values. In the Eco mode,
the system does not react to changes in temperature as
quickly as in the normal mode. It first examines in which
direction the temperature is changing before it starts to
heat or cool the supply air.
This green operation mode does not reduce comfort
notably, but it does reduce costs.
Setting:
1
Press button
. First, the text
ECO
will be
displayed for a short period of time. Then the
display will return to the standard view. The
ventilation system will enter the selected mode.
Returning to the Home mode:
1
Press button
. First, the texts
ECO
and
oFF
will
be displayed for a short period of time. Then the
display will return to the standard view.
Heating mode
In the Heating mode, the supply air is heated using an
integrated heater. Setting:
1
Press button
for 3 seconds. First, the text
HEAt
will be displayed for a short period of time. Then
the display will return to the standard view.
Returning to the Home mode:
1
Press button
for 3 seconds. First, the texts
HEAt
and
oFF
will be displayed for a short period of time.
Then the display will return to the standard view.
Range hood mode
In the range hood mode, the unit boosts the ventilation
and removes fumes from the stove more efficiently. When
the range hood has been connected to the unit and the
range hood boosting has been activated from the hood,
the text ‘PdC’ is displayed on the screen. At that point, the
unit’s mode cannot be changed from the eWind control
panel.
Returning to the Home mode:
1
Press button
for 3 seconds. First, the text
oFF
will be displayed for a short period of time. Then
the display will return to the standard view.
The default duration of the Fireplace mode is 10
minutes, and it can be selected no more than
twice a day. When the period has elapsed, the
system will return to the previous mode.
The heater does not heat the supply air if the
outdoor temperature e25°C.
The selected Eco mode will be switched off if the
outdoor temperature e25°C. The mode
will be switched back on when the outdoor
temperature drops below +25°C.
The Fireplace mode can also be selected using an
external Fireplace button (if installed).
NOTE
NOTE
NOTE
If a range hood has been connected to the unit,
the fireplace mode will not be available.
Summary of Contents for Pelican Z eWind
Page 24: ...24 2016 1254 2014 A A ENERGIA ENERGIJA ENERGY ENERGIE ENERGI PELICAN Z A 47 dB 654 m3 h...
Page 25: ...25 Ilmanvaihtolaitteen k ytt ja yll pito ohje...
Page 26: ...26 Pelican Z eWind Drift och underh llsanvisningar f r ventilationsaggregatet Svenska...
Page 48: ...48 2016 1254 2014 A A ENERGIA ENERGIJA ENERGY ENERGIE ENERGI PELICAN Z A 47 dB 654 m3 h...
Page 49: ...49 Drift och underh llsanvisningar f r ventilationsaggregatet...
Page 50: ...50 Pelican Z eWind Drift och underh llsanvisningar f r ventilationsaggregatet Norsk...
Page 72: ...72 2016 1254 2014 A A ENERGIA ENERGIJA ENERGY ENERGIE ENERGI PELICAN Z A 47 dB 654 m3 h...
Page 73: ...73 Drifts og vedlikeholdsinstrukser for ventilasjonsenheten...
Page 74: ...74 Pelican Z eWind Operating and maintenance instructions for the ventilation unit English...
Page 96: ...96 2016 1254 2014 A A ENERGIA ENERGIJA ENERGY ENERGIE ENERGI PELICAN Z A 47 dB 654 m3 h...
Page 97: ...97 Operating and maintenance instructions for the ventilation unit...
Page 98: ......
Page 99: ......