Ventilation unit operation and maintenance instructions

Replacing filters, left-handed model

2

3

4

5

1

ilmanvaihtolaite

ventilation unit

TYYPPI/TYPE:

W/ V/ HZ / A:

www.enervent.com

SRJ. NRO/SERIAL NO: 

IP 20

PINION EWIND E LEFT 

F7

M5

11 kg

!

HEX 4

Summary of Contents for Pinion

Page 1: ...19 October 2017 Enervent Pinion Ventilation unit operation and maintenance instructions ...

Page 2: ...2 Copyright Enervent 2017 Unauthorised copying and distribution is forbidden ...

Page 3: ...T USE OF THE VENTILATION 9 Use of the ventilation during the cold season 9 ADDITIONAL FUNCTIONS 10 Service reminder display 10 Time for next service 10 Set up display 10 ADJUSTMENTS 10 Supply air is too warm 10 Supply air is too cold 10 Ventilation is noisy 11 Indoor air is too humid 11 Ventilation does not work 11 MAINTENANCE 12 Service reminder 12 Filters 12 Replacing filters left handed model 1...

Page 4: ...nual may not be used by persons including children with reduced physical sensory or mental capacity or without sufficient experience or knowledge unless a person responsible for their safety is supervising and counselling in the use of the equipment PURPOSE OF USE The purpose of the unit is to improve the quality of indoor air and its primary function is ventilation The unit is also used for the r...

Page 5: ... the reason for the malfunction before starting the unit again Wait for two 2 minutes after switching off the unit power before you commence with the maintenance Although the power is switched off the fans continue running and the after heating coil stays hot for a while DANGER DANGER WARNING WARNING Should you need any technical support refer to the equipment type and serial number in the type pl...

Page 6: ...ts the settings for each operation mode when installing the ventilation unit The control panel is usually in standby mode where the display is dimmed You can activate the panel by pressing any button The eWind control panel The eWind control panel When the ventilation system has been carefully designed and installed any actions from the users are seldom needed The user can just relax and enjoy goo...

Page 7: ...y be useful when you light a fire in the fireplace To select 1 Press button for 3 seconds Text on will be displayed for a short period of time and then followed by F PL Home mode 2 When you are at home the ventilation unit functions normally in Home mode To select 1 Go to mode 2 by pressing button The ventilation system will enter the selected mode Home mode boosted ventilation 3 When you need mor...

Page 8: ...tton for 3 seconds The texts HEAt and oFF will be displayed for a short period of time Next the display will return to the standard view Hood mode In Hood mode the unit will boost ventilation and remove cooking smells from the cooker more efficiently When the cooker hood has been connected to the unit and the hood boosting has been activated from the hood the text PdC will be displayed on the scre...

Page 9: ...ays in order to keep out the heat of the sun Dress more warmly on cold days This will help you to save a lot of energy Use only spare parts approved by Enervent Use original filters only They have been designed to ensure the best possible performance of your ventilation system Use Eco mode in order to save energy and reduce costs without compromising the quality of indoor air EFFICIENT USE OF THE ...

Page 10: ...ase switch off Eco mode NOTE ADDITIONAL FUNCTIONS ADJUSTMENTS Supply air is too warm If the air coming from the ventilation system is too warm 1 Go to a lower supply air target temperature by pressing button The temperature value on the panel will change and the ventilation system will be adjusted according to the set target temperature Supply air is too cold If the air coming from the ventilation...

Page 11: ... Check that the fans are clean and that they do not require cleaning 4 If the fans are dirty clean them as instructed in the maintenance instructions 5 Check that the automated humidity boosting for removing moisture is not on 6 Open the Information display and browse to the parameter n1 If the parameter is visible the humidity boosting is on Indoor air is too humid In addition to feeling the humi...

Page 12: ... The required maintenance usually includes the following tasks replacing the filters cleaning the heat exchanger in connection with cleaning the ventilation ducts cleaning the fans in connection with cleaning the ventilation ducts checking the condensation water discharge pipe Cassette filters can be cleaned by using compressed air which extends the maintenance interval at the maximum to six 6 mon...

Page 13: ...t operation and maintenance instructions Replacing filters left handed model 2 3 4 5 1 ilmanvaihtolaite ventilation unit TYYPPI TYPE W V HZ A www enervent com SRJ NRO SERIAL NO IP 20 PINION EWIND E LEFT F7 M5 11 kg HEX 4 ...

Page 14: ...14 Replacing filters right handed model 2 3 4 5 F7 M5 1 ilmanvaihtolaite ventilation unit TYYPPI TYPE W V HZ A www enervent com SRJ NRO SERIAL NO IP 20 PINION EWIND E RIGHT 11 kg HEX 4 ...

Page 15: ...15 Ventilation unit operation and maintenance instructions ADDING WATER TO THE WATER TRAP REMOVAL OF THE CONDENSATION WATER Left handed model Right handed model ...

Page 16: ...t skids The heat exchanger motor is damaged If the drive belt is damaged take the spare belt into use and clean the outer surface of the heat exchanger Have the new belt and the motor of the heat exchanger replaced by a maintenance company authorised by the manufacturer The ventilation unit switches to malfunction mode and the fans oper ate with minimum power The alarm is auto matically reset when...

Page 17: ...17 Ventilation unit operation and maintenance instructions ...

Page 18: ...18 ...

Page 19: ...19 Ventilation unit operation and maintenance instructions ...

Page 20: ... sec 120 min Acknowledge the FILS service reminder by pressing any key on the eWind control panel for 5 seconds F PL will not be in use if a cooker hood is connected to the equipment Press the Mode button for 3 seconds The text on will be displayed for a short period of time and then followed by F PL User s quick guide version 19 10 17 ...