Page 29
Installation and Operation Manual - Harmony 2.3
ENGLISH
APPLIANCE CLEARANCES (INSTALLATION
WITH SINGLE WALL PIPE CONNECTOR)
APPLIANCE CLEARANCES (INSTALLATION
WITH DOUBLE WALL PIPE CONNECTOR)
Canada
USA
Canada
USA
A
14 ½" (368 mm)
11" (279 mm)
A
6" (152 mm)
6" (152 mm)
B
22" (559 mm)
22" (559 mm)
B
22" (559 mm)
22" (559 mm)
C
12" (305 mm)
12" (305 mm)
C
12" (305 mm)
12" (305 mm)
K
48" (1220 mm)
48" (1220 mm)
K
48" (1220 mm)
48" (1220 mm)
L
84" (213 cm)
84" (213 cm)
L
84" (213 cm)
84" (213 cm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
1
FROM PIPE CONNECTOR WITH
SINGLE WALL PIPE CONNECTOR
DISTANCES
1
FROM PIPE CONNECTOR WITH
DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
18" (457 mm)
14 ½" (368 mm)
D
9 ¼" (235 mm)
9 ¼" (235 mm)
E
31 ½" (800 mm)
31 ½" (800 mm)
E
31 ¼" (794 mm)
31 ¼" (794 mm)
F
21 ¾" (552 mm)
21 ¾" (552 mm)
F
21 ½" (546 mm)
21 ½" (546 mm)
7.2.1 Clearances with heat shield AC02710
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use
of a heat shield certified with the single wall pipe connector to be used as close as 6" from
combustible materials must be used. Only in this case, the same clearances as a certified
double wall pipe connector can be used.
APPLIANCE CLEARANCES (INSTALLATION
WITH DOUBLE WALL PIPE CONNECTOR)
DISTANCES
1
FROM DOUBLE WALL PIPE
CONNECTOR
Canada
USA
Canada
USA
A
3" (76 mm)
3" (76 mm)
D
6 ¼" (159 mm)
6 ¼" (159 mm)
B
4" (102 mm)
4" (102 mm)
E
13 ¼" (337 mm)
13 ¼" (337 mm)
C
3" (76 mm)
3" (76 mm)
F
12 ½" (318 mm)
12 ½" (318 mm)
K
48" (122 cm)
48" (122 cm)
L
84" (213 cm)
84" (213 cm)
1
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.