32
Destination 2.3 Installation and Operation Manual
Clearances for mobile homes
MOBILE HOME APPLIANCE CLEARANCES
(INSTALLATION WITH DOUBLE WALL PIPE
CONNECTOR)
CANADA
USA
A
10" (254 mm)
10" (254 mm)
B
17" (432 mm)
17" (432 mm)
C
8" (203 mm)
8" (203 mm)
K
48" (1220 mm)
48" (1220 mm)
L
84" (213 cm)
84" (213 cm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES* FROM PIPE CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
13½" (343 mm)
13½" (343 mm)
E
28¼" (718 mm)
28¼" (718 mm)
F
17¾" (451 mm)
17¾" (451 mm)
*The pipe distances listed in this table refer to the distances obtained when the stove is
installed in accordance with the appliance clearances above mentioned. However, you can
install the stove at reduced clearances; follow the instructions in Section 7.4: Reducing Wall
and Ceiling Clearances Safely. Where they are followed, the new distance of the pipe to
combustible materials must be respected in the appropriate certification of the pipe.