22
Step 2
Wire the AC wire refer to below instructions.
• Screw the green-yellow wire to the ground terminator in the AC connector (see figure 21).
• Screw the blue wire to the N(Neutral) terminator in the AC connector.
• Screw the black or brown wire to the L(Line) terminator in the AC connector.
Figure 21:
AC connector
Step 3
Check that all wires are well fixed (see figure 22).
connected wires
socket element
threaded sleeve
pressure screw
Figure 22
Step 4
Screw down the threaded sleeve (see figure 23).
socket element with
threaded sleeve
pressure screw
Figure 23
Step 5
Screw down the pressure screw (see figure 24).
socket element with
threaded sleeve
pressure screw
Figure 24