Appendix 2 — UNDERSTANDING THE LED
FLASHES
A.
Arming indicator
— Flashes quickly
during the 30-second rearm or passive
arming countdown.
B.
Door open indicator
— OFF when a
hardwired door is opened during the 30-
second rearm or passive arming
countdown.
C.
Armed indicator
— Flashes when the
alarm is armed.
D.
Disarmed indicator
— OFF when the
alarm is disarmed.
E.
One-time override of passive
arming
— Steady ON after VET button is
pressed once.
F.
RF reception indicator
— ON while
transmitter button is pressed.
G.
Valet mode indicator
— Flashes slowly if
the ignition switch is turned OFF (no flash if
ignition is ON).
Appendix 1 — UNDERSTANDING THE
SIREN CHIRPS AND LIGHT FLASHES
A.
1 chirp —
When valet mode is successfully
entered.
B.
1 chirp/flash
:
• When transmitter button #1 is pressed,
the alarm is armed.
• When a door is closed, the alarm will
arm in 30 sec. (passive arming).
• 30 sec. after ignition switch is turned
OFF and all doors are closed (or 30
seconds after delayed domelights turn
OFF), the alarm is armed (passive
arming with switch sensing).
C.
2 chirps —
When valet mode is
successfully exited.
D.
2 chirps/flashes
— When transmitter
button #1 is pressed, the alarm is
disarmed.
E.
3 chirps/flashes —
When pressing
transmitter button #1 to arm the alarm,
indicates the alarm arms even though it is
not set properly (door not closed, or
broken switch, or domelight is still ON, see
ZONE BYPASS on page 5).
F.
3 flashes —
When pressing transmitter
button #1 then button #2, indicates
sensor's pre-intrusion function is bypassed.
G.
4 flashes —
When transmitter button #1
is pressed, indicates alarm in valet.
H.
5 chirps/flashes
— Pre-intrusion warns
potential thieves or vandals who trigger the
first stage of a dual-stage sensor that your
car is protected by an alarm.
I.
7 flashes —
When the alarm is disarmed,
indicates the alarm was triggered while you
were away.
NOTE — The chirps for arm, disarm, pre-
intrusion, zone bypass, and valet can be
deleted (see CHIRP DELETE, page 6).