ENFORCER Voice Dialer
SECO-LARM U.S.A., Inc.
5
Programming the Voice Dialer:
You must enter setup mode to program the dialer functions. While in setup mode, if no key is
pressed within 20 seconds, the dialer will automatically exit and return to standby mode.
Entering Setup Mode:
To enter setup mode:
1.
Press the ENTER button.
2.
Type in the current PIN (the factory preset PIN is 8888) on
the keypad.
3.
Press the ENTER button again. You should hear a single
beep and the first screen of the setup menu will appear.
Setting and Changing the PIN
In setup mode:
1.
Press the DOWN button until you see the "07 Password" on
the display or press 07 on the keypad.
2.
Press the ENTER button. The current PIN will be shown on
the display.
3.
Press ENTER again, type in the new PIN (4 digits), and
press ENTER.
4.
Press the ESC button to return to the settings menu to program other functions.
5.
Press the ESC button again to exit the setup mode.
NOTE:
If you forget your PIN, you must reset the dialer, deleting all settings and data. Disconnect
the power and then power up while holding down the ENTER button until you hear a single
long beep. This deletes all settings and data from the dialer (See pg. 11).
Setting Alarm Phone Numbers
You can program up to 6 alarm numbers. In setup mode:
1.
If "01 Alarm Number" is not shown on the display, press the
UP button until it appears, or press 01 on the keypad.
2.
Press the ENTER button. The first alarm number will show
on the screen (if already programmed), otherwise "1:" will
appear followed by a blank line.
3.
Press ENTER to program or overwrite the first number or press the DOWN button to choose the
second and following number locations (up to 6 phone numbers) and press ENTER.
4.
Type in the number, including the area code if that is required (up to 14 digits).
5.
Press the ENTER button to save the number. A single beep will sound.
6.
Press the UP or DOWN button to move to another location to enter another number and follow
the same procedure.
7.
When finished, press the ESC button to return to the settings menu to program other functions.
8.
Press the ESC button again to exit the setup mode.
Enter Password:
8888
Menu(1-12)
07 Password
Menu(1-12)
01 Alarm Number
Password
8888
Enter Password:
1234
Menu(1-12)
01 Alarm Number
Alarm Number
1:
Auto Dialer
Ready