ENFORCER Outdoor Stand-Alone Keypads
16
SECO-LARM U.S.A., Inc.
Quick Reference Guide
Operation Function
Action
Enter an Output #1 user code
Directly enter on the keypad
Enter an Output #2 user code
Directly enter on the keypad
Ring doorbell
Press (if programmed)
Enter Programming Mode
Enter the master code twice
Exit Programming Mode
Press
Reset or restore the keypad
Please see full instructions on page 14
Program the proximity reader
Please see full instructions on pages 10 and 13
The following functions are performed
after
entering Programming Mode.
*After programming these functions, press to return to Programming Mode.
Operation Function
Step 1
Step 2
Step 3
Change the master code
Enter 3
Enter the new Master
Code twice
Program a new Output #1
user code
Enter a 3-digit
user ID
(from 000~999)
Enter a user code.
Program a new Output #2
user code*
Enter 4
Enter a 2-digit user ID
(from 00~09)
Enter a new user
code.
Deleting an Output #1 user *
Enter a 3-digit
user ID
(from 000~999)
Enter
Deleting an Output #2 user * Enter 4
Enter a 2-digit user ID
(from 00~09)
Enter
Set Output #1 timer
Enter 1
Enter number of seconds
(from 00~99)
Set Output #2 timer
Enter 5
Enter number of seconds
(from 00~99)
Set Output #2 function
Enter 2
Enter:
01
for user codes
02
for doorbell
Set tamper alarm
Enter 6
Enter:
01
for OFF
02
for ON
NOTICE:
The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy
is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice.
SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2011 SECO-LARM U.S A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without
the written permission of SECO-LARM.
WARRANTY
This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period
of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of
any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed
to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if
for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in
material and workmanship. The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or
repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damages of any kind to the purchaser or anyone else.
Mi-SK-x323-SxQ_1109.docx
PICCN2
SECO-LARM
®
U.S.A., Inc
.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
E-mail: info@seco-larm.com
Note:
For complete programming instructions, please see page 10,